3.5.1. FIREING
Check before first heating
:
– System pressure (heating water pressure):
The system must be filled and vented. With the system cold, pressure should be at least 1.0
bar (maximum
1.8 bar).
– Ventilation:
Please make sure the installation room is well ventilated. The air supply must be as free of
dust as possible.
– Flue:
Please have the chimney sweep check the flue regularly, and, if necessary, clean it.
– Barriers:
Check that the barriers installed in the heating system are set correctly.
– The boiler should be cleaned (combustion chamber grate, ash tray and other parts, as
required)
.
The height of the combustion chamber grate (
image
4, 6
) shall be adjusted according to the
expected need for heating the room. (Note: in case of partially filled combustion chamber, the
grate can be lifted also while the boiler is operation, paying attention to avoid fuel is blocked).
Pull out the firing handle to the limiter G (
image
3
), put the regime selection handle in position
„baking“ and fire the boiler (see
image
5
).
After ignition, put the wood into the combustion chamber (not higher than is shown in the
image
2
) and fire the boiler and return the ignition handle back into boiler to the limiter (see
image
3
). As intensive initial firing as possible is recommended so that boiler reaches
optimal temperature of 75-85°C as soon as possible. Adjust the draught controller to maintain
max. water temperature in the boiler at 85-90°C. Using the selection handle on the boiler
front side set the operating regime (see
image 5
).
If intensive need for baking or cooking occurs, at lower or no need for the room heating (in
warmer days), it is necessary either to open some radiators or built in a sanitary water tank
with tube heat exchanger via which the boiler would heat sanitary water and take away
surplus of heat.
Fireing, refuelling, summer mod, winter mod
3.5.2. REFUELLING - continuing heating operation
Open heating door with care as flue gas may escape!
For low emissions and high efficiency, we recommend:
– refuelling at short intervals (30–60 min)
3.5.4. SUMMER MOD
3.5.3. WINTER MOD
Height-adjustable grate at top (image
6
).
The height-adjustable grate is in the bottommost position (image
6
)
.
38
Technical data
BIO-PEK B 17, 23, 29
ENG