16
17
Changing the Open Code 1
Changing the Open Code 2
Changing the Programming Code
The Open Code 1 is mainly used as a method to quickly test the Lock Strike Relay during installation.
The Default factory Setting for the Open Code 1 is 2580. When the first user is added to the
controller, the default Open Code will automatically be deleted, ready for a new Open Code 1 to
be re-entered.
1) Enter Programming Mode
2) Press
“1”
to enter
Menu 1
• The Mode LED will turn red
3) Enter the new 4-digit code you wish to set as Open Code 1
4) System returns to Normal Mode
• You will hear 3 beeps
• The Door LED will turn off
• The Mode LED will turn green
Note:
- Open Code 1 does not function in Secure Mode.
- Wrong entries will return the controller to Normal Mode.
- Code 0000 will erase and deactivate the Open Code.
1) Enter Programming Mode
2) Press
“2”
to enter
Menu 2
• The Mode LED will turn orange
3) Enter the new 4-digit code you wish to set as Open Code 2
4) System returns to Normal Mode
• You will hear 3 beeps
• The Door LED will turn off
• The Mode LED will turn green
Note:
- Open Code 2 does not function in Secure Mode.
- Wrong entries will return the controller to Normal Mode.
- Code 0000 will erase and deactivate the Open Code.
1) Enter Programming Mode
2) Press
“3”
to enter
Menu 3
• The Mode LED will turn green
3) Enter the new 4-digit code you wish to set as Programming Code
4) System returns to Normal Mode
• You will hear 3 beeps
• The Door LED will turn off
• The Mode LED will turn green
Note:
- Programming Code can not be erased, i.e. the code 0000 is not valid and will not erase
the Programming Code.
The Open Code 2 is mainly used as a method to quickly test the Lock Strike Relay during installation.
The Default Factory Setting for the Open Code 2 is 0852. When the first user is added to the controller,
the default Open Code will automatically be deleted, ready for a new Open Code 2 to be re-entered.