8
9
Wiring Diagrams
Normal, Secure & Master Users
SA1DK
SA1DK
BL-D40
Wiring the Lock Strike Relay and REX
Wiring the BL-D40 External Sounder
The SA1DK accepts up to 500 users and provides entry via the use of PIN codes. Each user is
provided with two code memory slots, Memory Slot 1 (Primary Code) and Memory Slot 2 (Secondary
Code).
The way in which the two memory slots are programmed determines a users access level and also
determines the way in which the SA1DK grants access in its three Modes of Operation.
There are three user levels:
Normal User
A Normal User only has a Primary Code and is only granted access when the SA1DK
is in Normal or Bypass Mode.
Secure User
A Secure User must have a Primary and Secondary Code programmed, the two codes
must not be the same. The Secure User can gain access when the SA1DK is in any of
its three Modes of Operation. In Normal Mode the Secure User must use their Primary
Code to gain entry. In Secure Mode the Secure user must present both their Primary
and Secondary Codes in order to gain entry.
Master User
A Master User must have both Primary and Secondary Codes programmed with the
same PIN code. The Master User can gain access during any Mode of Operation by
presenting their PIN code to the controller. (The Master User is convenient but is less
secure than a Secure User).