PAN-10 and PAN-12 Sensor installation guide 

IC compliance statement  

This device complies with Innovation, Science and Economic Development 
Canada license-exempt RSS standard(s). Operation is subject to two conditions:  

1.  This device may not cause harmful interference, and  

2.   This device must accept any interference that may be received or that 

may cause undesired operation.  

A distance of at least 10 cm between the equipment and all persons should be 
maintained during the operation of the equipment.  

 
Le présent 

appareil est conforme aux CNR d’Industrie Canada applicables aux 

appareils radio exempts de licence. L’exploitation est autorisée aux deux 

conditions suivantes: 

 

1.  

l’appareil ne doit pas produire de brouillage, et

  

2.  

l’utilisateur de l'appareil doit a

ccepter tout brouillage radioélectrique 

subi, même si le brouillage est susceptible d'en compromettre le 
fonctionnement.  

Une distance d’au moins 10 cm entre l’équipement et toutes les personnes 
devraient être maintenues pendant le fonctionnement de l’équi

pement.  

Product end of use handling (WEEE) -  
Waste of Electrical and Electronic Equipment  

Panoramic Power is committed to protect the global environment and helping  
our customers with recycle responsibilities. Disposal of electrical and electronic 
products must be done according with the local and national regulations. You  
can return your product to a local collection point.  

For information about your disposal or collection points, call your distributer or 
vendor, or contact 

[email protected]

 

 

 

 

 

 

Содержание Panoramic Power PAN-10

Страница 1: ...1 Version 1 4 January 2018 Operation and maintenance manual Unit number 0000 PAN 10 and PAN 12 Sensor installation guide...

Страница 2: ...tion However there is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the...

Страница 3: ...ux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout bro...

Страница 4: ...installation guide Contents Overview 5 Workflow 5 Unpacking the hardware 5 Safety precautions 6 Hardware description 6 Mapping the site 7 Installing a sensor Attaching the sensors to the circuits Reg...

Страница 5: ...ic field and also use the field as a power source The sensors do not require any maintenance Data collected by the sensors is sent to a bridge which in turn transfers the information to the Panoramic...

Страница 6: ...The sensor must not be installed lying or touching bus bars or any other non insulated exposed conductors Installation is possible both on external entry exit conductors before the terminal strip as w...

Страница 7: ...on in Panoramic Power System Attaching the sensors to the circuits To install a sensor follow these steps 1 Open the cover of the electrical panel board 2 Make sure you have a plan that indicates the...

Страница 8: ...r particles If necessary wipe it with a dry cloth Note Whenever possible avoid installing the sensor behind wires and position it at the front of the panel board 8 Place the opening of the sensor on a...

Страница 9: ...ooting If the sensor vibrates after installation you can hear the vibration noise or feel it when touching the sensor it means that the sensor is not properly closed Try to press the two parts of the...

Страница 10: ...rted 50 Hz EU JPE 60 Hz US JPW 50 Hz EU JPE 60 Hz US JPW Transmission frequency 434 MHz EU 902 928 MHz US 923 MHz JPE JPW 434 MHz EU 902 928 MHz US 923 MHz JPE JPW Transmission power ERP 0 dBm Max 4 d...

Страница 11: ...t the sensor is completely closed all four pins screws are in place If they are try pressing the sensor again like you did when closing it The sensor is not sending measurements Make sure the circuit...