5.  Press the two sides of the opener to release the sensor cover.  

 

 

 

 

 

 

 

Figure 5. Press the opener to release the cover.  

 

6.  Open the four screws.  

 

 

 

 

 

7.  Make sure the four core surfaces are free of dust or any other particles. 

If necessary, wipe it with a dry cloth  

Note

 Whenever possible, avoid installing the sensor behind wires and position it 

at the front of the panel board.  

8.  Place the opening of the sensor on a clean section of the electrical cable 

with the arrow on the label pointing towards the load, so that the sensor 
ID and barcode are visible and easily readable.  

9.  Close the sensor cover, snapping it into its place (in 225A screw back the 

cover) and making sure that all four pins are properly inserted and the 
sensor is tightly closed.  

10. You can learn more about sensors installation 

in this video clip.  

 

Содержание Panoramic Power PAN-10

Страница 1: ...1 Version 1 4 January 2018 Operation and maintenance manual Unit number 0000 PAN 10 and PAN 12 Sensor installation guide...

Страница 2: ...tion However there is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the...

Страница 3: ...ux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout bro...

Страница 4: ...installation guide Contents Overview 5 Workflow 5 Unpacking the hardware 5 Safety precautions 6 Hardware description 6 Mapping the site 7 Installing a sensor Attaching the sensors to the circuits Reg...

Страница 5: ...ic field and also use the field as a power source The sensors do not require any maintenance Data collected by the sensors is sent to a bridge which in turn transfers the information to the Panoramic...

Страница 6: ...The sensor must not be installed lying or touching bus bars or any other non insulated exposed conductors Installation is possible both on external entry exit conductors before the terminal strip as w...

Страница 7: ...on in Panoramic Power System Attaching the sensors to the circuits To install a sensor follow these steps 1 Open the cover of the electrical panel board 2 Make sure you have a plan that indicates the...

Страница 8: ...r particles If necessary wipe it with a dry cloth Note Whenever possible avoid installing the sensor behind wires and position it at the front of the panel board 8 Place the opening of the sensor on a...

Страница 9: ...ooting If the sensor vibrates after installation you can hear the vibration noise or feel it when touching the sensor it means that the sensor is not properly closed Try to press the two parts of the...

Страница 10: ...rted 50 Hz EU JPE 60 Hz US JPW 50 Hz EU JPE 60 Hz US JPW Transmission frequency 434 MHz EU 902 928 MHz US 923 MHz JPE JPW 434 MHz EU 902 928 MHz US 923 MHz JPE JPW Transmission power ERP 0 dBm Max 4 d...

Страница 11: ...t the sensor is completely closed all four pins screws are in place If they are try pressing the sensor again like you did when closing it The sensor is not sending measurements Make sure the circuit...

Отзывы: