SKU 93680 For technical questions, please call 1-800-444-3353 PAGE 8
3.
Push the Magazine Assembly (82) back into the Nailer and secure it with the
Lock Lever (63).
OPERATING THE NAILER
1.
Attach the Nailer to the air supply at the Quick Connector (48). Start your
compressor and check the pressure, making sure it is set at the recommended 50-
110 PSI. Do not exceed the maximum 110 PSI.
2.
Rotate the Exhaust Valve Collar (1) so that the exhaust air blast will be directed
away from the operator.
WARNING: Always keep hands away from the workpiece when firing.
3.
To fire, place the Driver Guide (54) of the Nailer on the workpiece. The Nailer
should not fire if the Driver Guide is not depressed. Once depressed, gently and
briefly squeeze the Trigger (42) once; one Brad will be fired.
4.
Do not press the Driver Guide (54) against the workpiece with extra force. Allow
the tool to do the work. Always allow the tool to recoil off the work surface.
5.
When finished using the Nailer, always disconnect the tool from its air supply.
Empty the Magazine Assembly (82) completely of Brads. Attempt to fire the
Nailer into a piece of scrap wood to ensure it is disconnected and is incapable of
firing any Brads.
6.
Make sure to store the Nailer in a clean, dry, safe location out of reach of children.
DRIVER GUIDE (54)
MAGAZINE ASSY. (82)
TRIGGER
(42)
QUICK CONNECTOR (48)
EXHAUST VALVE COLLAR (1)
LOCK LEVER