5.
Connect the air supply to the tool at the Quick Connector (48). Set the regulator
at the recommended 50 to 110 operating PSI. Do not exceed the maximum
110 PSI.
6.
Test the tool by depressing the Driver Guide (54) against the workpiece without
pulling the Trigger (42). The tool must not cycle (fire). If it cycles (fires), stop
immediately and have it repaired by a qualified service technician.
7.
Hold the tool away or off the workpiece. The Driver Guide (54) of the tool should
return to its original position. Squeeze the Trigger (42). The tool should not
cycle (fire). If the tool cycles (fires), stop immediately and have it repaired by a
qualified service technician.
8.
Depress the Driver Guide (54) against the workpiece and squeeze the Trigger
(42). The tool must cycle (fire) only once. Release the Trigger and squeeze it
again. The tool must cycle (fire) only once. With the Trigger held, carefully lift
the Nailer and press it against the workpiece again. The tool must not cycle
(fire). If it fails to perform in the manner explained in bold, have it repaired by a
qualified service technician.
LOADING BRADS
WARNING: Always wear ANSI approved impact safety goggles when
reloading or performing any other maintenance on this tool. Other people in
the work area must also wear ANSI approved impact safety goggles.
1.
Depress the Lock Lever (63) to release the Magazine Assembly (82) and pull the
Magazine out fully.
2.
Place a full clip of the desired size Brads (5/8” to 2”) in the Magazine Assembly
(82). Up to 110 Brads may be loaded in the Magazine.
SKU 93680 For technical questions, please call 1-800-444-3353 PAGE 7
MAGAZINE ASSY.
(82)
LOCK LEVER
(63)