15
NOTE: Changing this variable will automatically
change the HIGH to MEDIUM differential. The HIGH
to MEDIUM Differential is a ratio of the MEDIUM to
HIGH Differential and is a numeric value from 1 to
10. When the water temperature is this far above the
temperature at which the controller changed into
HIGH mode, the controller will change to MEDIUM
mode.
4. Low Burner Temperature: 300˚F (149˚C)
The controller will operate in Ignition mode until the
burner temperature reaches this value plus the Ignition
Differential (variable 5). If the burner temperature drops
below this value during MEDIUM mode, the controller will
switch to Ignition mode. Adjustable from 100 to 470.
5. Ignition Differential: 100˚F (38˚C)
The controller will continue in Ignition mode until the
burner temperature is higher than the Low Burner
Temperature plus this value (300˚F + 100˚F = 400˚F). If
a third attempt is required, this value is added to the
target temperature again (300˚F + 100˚F + 100˚F = 500˚F).
Adjustable from 1 to 199.
6. Ignition Duration: 10 min. (wood pellets)
20 min. (corn)
The amount of time in minutes Ignition mode will run.
The controller will make up to three attempts at ignition,
each for this amount of time, before a Fire Out mode.
Adjustable from 1 to 100.
7. Pellet Mode Enabled: 1
By default, this variable is set to 1 and the controller
is configured to operate with premium quality wood
pellets as a fuel source. The controller also has a modified
program to help ignite lesser quality wood pellets and/or
corn. To enable, change this setting to 0. If set to 0, several
other variables will automatically change to the corn
default values.