5

To disable or enable time periods:
a.

 To disable unwanted periods go to the desired period (

2

 to 

4

)  using the 

PROGRAM

   or   buttons to navigate, ensure the correct period is highlighted 

with the flashing square symbol. Press and hold the   button for at least 2 seconds 

and the display will indicate the period has been removed from the program.

b.

 To enable periods again follow the same procedure as above, navigating to the 

already disabled period. To enable this period again press and hold the   button for 

at least 2 seconds.

Operating the EHE0200153

Choosing the Operating Mode

The thermostat can operate in three different modes: Automatic, Manual or Off. To 

set the operating mode press either of the 

AUTO

MAN 

or 

OFF 

buttons. The screen 

indicates which mode is currently active by displaying 

AUTO

MAN 

or 

OFF

.

• 

AUTO (automatic)

 mode sets the thermostat to follow the built-in temperature 

program (default or personalised). Operating the thermostat in this mode is the best way 

to maintain a high level of temperature comfort whilst maximising your energy savings.

• 

MAN (manual)

 mode sets the thermostat to act as a simple thermostat with a 

fixed setpoint throughout the day. The setpoint can be adjusted from 5°C to 35°C 

by using the     or   buttons. The thermostat will continue to maintain this 

temperature until another operating mode or temperature is selected.

• 

OFF

 mode sets the thermostat to control to a minimum temperature setting of 5°C 

(default) that acts as a frost protection measure for your home.

During Normal Operation

• 

Temperature Enquiry

  In 

AUTO

MAN

 and 

OFF

 operating modes the thermostat will display the current 

room temperature. To review the programmed ‘target’ temperature (the temperature 

which the thermostat is trying to maintain) press the   button. This ‘target’ 

temperature value will be displayed flashing for 5 seconds before returning to the 

current room temperature value. 

• 

Temperature Override

  During normal operation (

AUTO

 mode) the programmed temperature can be 

adjusted manually by pressing the     or   buttons or the   button. The ‘target’ 

temperature will be displayed and flash for 5 seconds - during this time the     or   

buttons can be used to modify the set value.

 

Note:

 This temperature override is cancelled at the next programmed temperature change.

Adjusting the Time

To adjust only the time during normal operation use the     or   buttons to adjust 

the time and press the 

 button again to confirm any changes.

Содержание EHE0200153

Страница 1: ...Wed Thu Fri Sat Sun OFFMANAUTO Ergonomic user interface featuring an OK button Large LCD Liquid Crystal Display Screen 4 independent temperature levels from 5 C to 35 C Built in Memory holds the user program indefinitely Features of the EHE0200153 Ergonomic user interface featuring an OK button Large LCD Liquid Crystal Display Screen 7 day heating program to match your lifestyle whilst maximising ...

Страница 2: ...On Indicator Temperature Display Temperature Change Buttons Temperature Enquiry Button 1 2 3 8 9 10 4 5 Operating Mode Buttons OK Button Battery Compartment Battery Cover Program Buttons Time Change Buttons 11 12 13 13 1 2 4 3 5 7 8 9 6 11 12 10 Controls Layout EHE0200153 User Guide 6 7 ...

Страница 3: ...iding it firmly back into the front of the thermostat STEP 2 Setting the Time To set the Date and Time a Press either of the or buttons once to enter time setting mode The LCD screen flashes the time digits when the unit is powered for the first time the display shows 12 00 b Use the or buttons to set the correct time then press the button to confirm Each press of the buttons will change the time ...

Страница 4: ... the button to move to step d d The temperature setting for period 1 will now be flashing To adjust this press the or buttons and confirm the setting again by pressing the button e The next time and temperature period will now be active Adjust this by repeating steps b d above until all 4 periods are set or press the AUTO button to run the program as set at any time Disabling Enabling Time Periods...

Страница 5: ...a simple thermostat with a fixed setpoint throughout the day The setpoint can be adjusted from 5 C to 35 C by using the or buttons The thermostat will continue to maintain this temperature until another operating mode or temperature is selected OFF mode sets the thermostat to control to a minimum temperature setting of 5 C default that acts as a frost protection measure for your home During Normal...

Страница 6: ...whole day To operate as a simple thermostat with one temperature throughout the day select the manual operating mode by pressing the MAN button Adjust the temperature by pressing the or buttons this can be set anywhere from 5 C to 35 C in 0 5 C steps The thermostat will continue to maintain this temperature until another operating mode is selected or the temperature is adjusted Symptom Blank Displ...

Страница 7: ...r Day Indicator Temperature Display Temperature Change Buttons Temperature Enquiry Button 1 2 3 9 10 11 4 5 Operating Mode Buttons OK Button Battery Compartment Battery Cover Program Buttons Copy Day Button Set Day Button Time Change Buttons 12 13 14 15 Controls Layout EHE0200154 User Guide 6 7 1 2 4 3 5 8 9 10 7 12 13 11 15 6 14 16 16 8 ...

Страница 8: ...o set the Date and Time a Press the DAY button once and the day indicator will begin to flash b Press the DAY button until the correct day is reached Day 1 Monday Press the button to confirm d Press either of the or buttons once to enter time setting mode The LCD screen flashes the time digits when the unit is powered for the first time the display shows 12 00 e Use the or buttons to set the corre...

Страница 9: ...Holding the button down will change the time quickly Note If you are pressing the or buttons and the display flashes the next period it means the next period will be pushed forward c Once the required time is reached press the button to confirm Note If the original time setting did not require adjustment press the button to move to step d Mon Tue Wed Thu Fri Sat Sun 4 3 2 1 The Built in Heating Pr...

Страница 10: ... ii Press the DAY button to move the day indicator to Tuesday Day 2 The program for that day can then be adjusted by following steps b to e Programs for the remaining days can be set in the same way using the DAY button to move to the next day To exit the programming mode select the desired operating mode by pressing the AUTO MAN or OFF buttons Note To run the adjusted program select the AUTO mode...

Страница 11: ...rol to a minimum temperature setting of 5 C default that acts as a frost protection measure for your home During Normal Operation Temperature Enquiry In AUTO MAN and OFF operating modes the thermostat will display the current room temperature To review the programmed target temperature the temperature which the thermostat is trying to maintain press the button This target temperature value will be...

Страница 12: ...this can be set anywhere from 5 C to 35 C in 0 5 C steps The thermostat will continue to maintain this temperature until another operating mode is selected or the temperature is adjusted Symptom Blank Display Power Loss Display shows flashing symbol Display shows symbol Remedy Check batteries are installed by removing the battery cover Check batteries have been installed in the correct orientation...