8
(1)
Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u
L
pA
= weighted continuous acoustic pressure level equivalent.
L
pCPeak
= maximum value of the weighted acoustic displacement pressure at the work place.
L
WA
= acoustic power level emitted by the machine.
(2)
Directive 2006/42/EC, annexe 1, point 2.2.1.1
Weighted root mean square in frequency of the acceleration the upper limbs are exposed to for each biodynamic
reference axis. Tests carried out in compliance with the indications contained in EN ISO 5349-1/2 Standard, and
under operating conditions much more severe than those normally found.
1. GENERAL CHARACTERISTICS
B70M-P36
B85M-P36
Operating pressure
bar (psi)
700 (10153)
850 (12328)
Oil supply
l / min (US gpm)
0,67 (0.19)
0,57 (0.16)
Oil reservoir capacity
cm
3
(cu. in.)
1100 (67.1)
Degree of protection
IP 44M (EN 60529)
Dimensions
Ref. to Fig. 8 page 4
Weight with battery
kg (lbs)
10 (22)
Motor
V
36
Operating temperature
°C (°F)
-20 to +50 (+4 to +122)
Recommended oil
ENI ARNICA ISO 22 or equivalents
Safety
maximum pressure valve
Rechargeable battery
type
CB3662L Li-Ion
Voltage / Capacity
V / Ah (Wh)
36 / 6.2 (223,2)
Weight
kg (lbs)
1,6 (3.5)
Acoustic noise
(1)
dB L
pA
69,8 (A) L
pCPeak
93 (C) L
WA
83,4 (A)
Vibrations
(2)
m/s
2
0,652
B70M-P36
B85M-P36
B70M-P36E
B70M-P36T
B70M-P36A
Battery charger
type ASC-ULTRA-
EU
ASC-ULTRA-
UK
ASC-ULTRA-
AUS/NZ
ASC-ULTRA-
USA/CAN
Input
Power
V / Hz
W
220 - 240 / 50 - 60
290
115 / 60
290
Output
V
/ A
14,4 - 36 / 6,5 max.
Weight
kg
0,97
ENGLISH