9
(1)
Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u
L
pA
= weighted continuous acoustic pressure level equivalent.
L
pCPeak
= maximum value of the weighted acoustic displacement pressure at the work place.
L
WA
= acoustic power level emitted by the machine.
(2)
Directive 2006/42/EC, annexe 1, point 2.2.1.1
Weighted root mean square in frequency of the acceleration the upper limbs are exposed to for each biodynamic
reference axis. Tests carried out in compliance with the indications contained in EN ISO 5349-1/2 Standard, and
under operating conditions much more severe than those normally found.
1. ELECTRO-HYDRAULIC BATTERY PUMP (RADIO CONTROLLED)
Operating pressure
psi (bar)
10,573 (729)
Oil supply
high speed - low pressure
low speed - high pressure
US gpm (l/m)
US gpm (l/m)
0.34 (1,28)
0.07 (0,25)
Motor
V DC
18
Radio receiver frequency
remote control
cutting head blade travel sensor
Mhz
Mhz
2405–2480
915 (USA CANADA AUSTRALIA)
Operating temperature
°F (°C)
+5 to +122 (-15 to +50)
Oil reservoir capacity
cu. in. (cm
3
)
58.6 (960)
Recommended dielectric oil
TOTAL DIEKAN 1640
Operating speed
Double speed action: operation and automatic
switching from a rapid advancing speed to a slower,
more powerful working speed
Degree of protection
IP 20
Dimensions
Ref. to Fig. 13 page 6
Weight with battery
lbs (kg)
12.8
(
5
,
8
)
Safety
double safety system,
electronic & mechanical safety valve
Acoustic noise
(1)
dB
L
pA
66.8 (A) L
pCPeak
88 (C) L
WA
82.8 (A)
Vibrations
(2)
m/s
2
0.318
Rechargeable battery
type
CB1870L Li-Ion
V / Ah (Wh)
18 / 7.0 (126)
Weight
lbs (kg)
2 (0,9)
Battery charger
ASC30-36
Input
type
USA/CAN
V / Hz (W)
115 / 60 (85)
Содержание B68M-P18A-KV-RC2