1. Press
to view the CALIBRATION
function.
2. Add a standard weight of 60 g (2.00 oz) to the outer
side, in any position.
.
3. Shift the standard weight from the outside to the
inside keeping the same position.
4. Turn the wheel until the standard weight is at the top
(12 o’clock).
5. Turn the wheel until the sample weight is in corre-
spondence to the centre-line of the weight clip.
Pressing the button
a default value is set.
6. Turn the wheel until the centre-line of the sample
weight is in correspondence to the laser beam.
Pressing the button
a default value is set.
7. End of calibration.
To cancel calibration at any time, press
6.5
AUTOMATIC GAUGES CALIBRATION
6.5.1 Rim distance gauge
Display the SETUP menu
1. Press
to view the rim distance
gauge CALIBRATION function.
2. Leave the distance gauge in rest position and press
3. Move the distance gauge pusher in line with the
adapter
surface and press
CALIBRATION COMPLETE
Return the gauge to rest position.
The wheel balancer is ready for operation.
In the event of errors or faulty operation, the writing
“
r.P.
”
:
ap
pears on the display : shift the gauge to the
rest position and repeat the calibration operation exactly
as described above. If the error persists, contact the
Technical Service Department. In the event of incorrect
input in the rim distance gauge calibration function, press
to cancel it.