background image

 

5. Press            to toggle showing the T1, T2, and T1-T2 

(differential temperature measurement) in the primary, 

secondary and tertiary display. 

6.

 

Press                  button to turn on the backlight. Press it 

again to turn off the backlight. Press                  button for 3 

seconds to start or exit Setup. (See "Changing Setup 

Options.") 

7.

 

Press              to scroll to the Setup option you want to 

change. Press              to increase the displayed setting. 

8.

 

Press              to scroll to the Setup option you want to 

change. Press                to decrease the displayed setting. 

9. Press                to enter a Setup option. Press              again 

to store the displayed setting in memory. 

 

 

 

 

 

 

 

 

 

 

Содержание DT-613

Страница 1: ...OPERATION MANUAL Professional Thermocouple Thermometers DIF Enter REC...

Страница 2: ......

Страница 3: ...Operating Temperature 0 C to C 4 F F Noncondensing Storage Temperature C C 14 F F Temperature Range K type thermocouples 200 C to 1372 C 328 F to 2501 F IR Temperature 30 C to 550 C 22 F to1022 F Temp...

Страница 4: ...Readout in C F or Kelvin K 5 Auto Power Off mode Sleep mode increases battery life Button 1 Press to turn the thermometer on or off 2 Press to step through the maximum minimum and average readings Whe...

Страница 5: ...n to turn off the backlight Press button for 3 seconds to start or exit Setup See Changing Setup Options 7 Press to scroll to the Setup option you want to change Press to increase the displayed settin...

Страница 6: ...s 8 Tertiary Display The elapsed time or T1 T2 reading 9 Low battery Replace the batteries 10 Min sec or hour min Display 11 MAX MIN AVG display Using the thermocouple s 1 Plug the thermocouple s into...

Страница 7: ...will show on the screen Changing Setup Options Use Setup to change offset sleep mode settings The thermometer stores the settings in its memory Setup Options Entering or Exiting Setup When the thermo...

Страница 8: ...lus the offset and the secondary display shows the offset You can store individual offsets for T1 T2 Auto Power Off mode The thermometer enters sleep mode default That is to say the meter will automat...

Страница 9: ...nd readings in the primary or secondary display Notes The display shows when a thermocouple is not connected The display shows OL overload when the temperature being measured is outside the thermocoup...

Страница 10: ...ompensate for the errors of a specific the thermocouple and IR temperature The allowable adjustment range is 5 0 C or 9 0 F 1 Plug the thermocouple into the input connector 2 Place the thermocouple in...

Страница 11: ...10...

Страница 12: ...11 v081120...

Отзывы: