HEAT/LIGHT/VENT INSTRUCTIONS

GENERAL NOTES

This Celsius product is designed only to be used as a fixed Heat/Light/Vent product, installed
into the ceiling. If the product is installed or used for any other purpose the warranty will be void.

Installation of this product must be completed by a registered electrician.

Handle product with care, remove the bulbs during installation.

The unit must be located and installed in accordance with the AS/NZS 3000:2007 and any local
regulation information for mounting in damp areas (please consult your local electrician for
information).

A means of disconnection must be incorporated in the fixed wiring in accordance with the wiring
rules.

The unit can be installed in any room that requires direct radiant heating and circulated air flow
such as bathrooms, ensuites, laundries, etc.

The unit must be installed in flat ceilings with a minimum height of 2 metres from the floor.

Do not install the unit directly above shower or bath recesses or enclosures.

The unit must not be installed in a position where water may splash onto the heat lamps.

At least 220mm height clearance in the ceiling cavity is required to ensure sufficient ventilation
for moisture to disperse.
Joists, beams and rafters shall not be cut or notched to install the appliance.

The unit must also be installed at least 400mm away from the walls.

The appliance shall under no circumstances, be covered with insulating material or similar
material.

For maximum efficiency to remove steam and odours, there must be an adequate air flow within
the room. To obtain maximum air flow ensure there is a gap under doors or open windows
slightly. A good test for this is that the fan should not change speed (or sound) when you close
or open the bathroom door.

220-240V 50Hz electrical supply is required. The unit can be connected to a lighting or power
circuit if loading permits. All electrical work must be carried out by a registered electrician in
accordance with AS/NZS 3000:2007 (please consult your local electrician for information). A
three gang switch is included to so the user can independently switch the Ventilation, Heat and
Light on and off. This needs to be installed in a position where it cannot be reached from the
bath or shower.

Heat lamps and light bulbs supplied with the unit are test bulbs only, these are not covered

Содержание CHL425W

Страница 1: ...For models CHL425W Heat Light Vent 4 Light with LED Centre Bulb OPERATING INSTRUCTIONS...

Страница 2: ...may overheat and become a fire risk Do not cover heat lamps or inlet of airflow by placing these areas of the appliance against any surface Do not mount appliance close to any heat source Do not opera...

Страница 3: ...led in a position where water may splash onto the heat lamps At least 220mm height clearance in the ceiling cavity is required to ensure sufficient ventilation for moisture to disperse Joists beams an...

Страница 4: ...on press one of the HEAT switches down and up to turn off To turn all 4 heat lamps on press both of the HEAT switches down and up to turn off Air Flow Requirements For maximum efficiency to remove ste...

Страница 5: ...ace by clips It is essential that additional screws not supplied are used to aid holding the unit in the ceiling Screw holes are provided in the flange for this purpose 2 strips of timber one on each...

Страница 6: ...with a safety thermal switch which will activate the fan to cool the unit if the heat generated by the heat lamps exceeds a certain level It is imperative that this feature is enabled Ensure power to...

Страница 7: ...ailer Celsius recommends the use of Elite heat lamps and light bulbs please note these items are not covered under warranty HEAT LIGHT VENT INSTRUCTIONS SUPPORT AND TECHNICAL ADVICE Celsius New Zealan...

Страница 8: ...annot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also en...

Отзывы: