18
3.1.2. Outdoor Passive Infrared Sensor Long Range. ( HP Outdoor sensor for and
E12 Panels)
Learn Button
1. Loosen the 4 screws of the Outdoor sensor and carefully remove the back cover.
2. Mounted on the cover is the outdoor sensor electronic board.
3. Connect the Battery the connector can only go one way.
4. Identify the Learn button on the PIR.
5. Press the Learn Button and check that the LED of the sensor comes on and stay’s on
for 2 to 3 seconds after you release the button.
6. Now press the learn button on the Control Panel the learn LED should switch on.
7. Press the Learn button on the sensor and hold for 3 sec.
8. The Control Panel Learn LED may switch off.
9. The Control Panel Learn LED should flash and then stop.
10. To program this device to a zone follow the steps in section 3.2 of this document.
Connecting the 2 tamper pins will enable the tamper signal. When disconnected, no
tamper signal will be generated by the sensor.
The walk test function is used for testing purposes. When the 2 walk test pins are
connected, the sensor can send a triggered signal approximately every 10 seconds
(opposed to the normal 3 minutes). To save battery power, these pins must be
disconnected when testing is completed.
Battery Connector
Tamper
Walk Test