13
V3.15.22
・
Installation Notes:
1. The unit is shipped with (4) wall mounting brackets, a 90° drain elbow, and a 10’ length of
1/2 ” I.D. condensate drain line. The required hardware is shipped loose with the unit.
a.
Model 6200VSi / 8200VSi (indoor installations): Select the desired set of mounting
holes, location #1, #2, #3, or #4 (shown above). The mounting brackets can be
used on either side of the wall.
b.
Model 6200VSx / 8200VSx (shaded outdoor installations): Select the desired set of
mounting holes, location #1, #2, or #3 (shown above). The rear cover uses hole
location #1. If this is also the desired location for the mounting brackets, first make certain
the rear cover is in place, and then install the mounting brackets over the rear cover.
2. If the mounting brackets are used in location #1 or #2, a shelf will be needed to support
the weight of the cooling unit.
3. To attach the mounting brackets, attach the side and top brackets to the unit using
(8) #8x3/8” sheet metal screws. The bottom bracket only attaches to the side
brackets – there are no mounting holes for the bottom mounting bracket in the case
of the cooling unit. Secure the top and bottom brackets to the side brackets with (4)
1/4-20x5/8” bolts and lockwashers (included).
4. Attach insulated foam tape to the mounting brackets on the side that will face the
wall to create an insulated and airtight seal between the wall and the brackets.
5. Once the cooling unit is installed, all cracks and gaps between the cooling unit and
the cellar should be sealed. A complete and proper seal must be made between the
cellar and the cooling unit to ensure that outside air does not enter the cellar. Use
sealant tape or caulking to seal the perimeter where the cooling unit touches the
cellar. Check the seal by having a helper stand in front of the cabinet while you shine
a flashlight around the cooling unit edges to discover any gaps in sealant.
6. Thread the drain elbow tightly to the condensate overflow drain line. Thread tape
is not required. Run the overflow drain tube to a gravity drain, routing so that the
tube forms a water trap near the unit. Charge the tube trap with water, then slide
the 1/2” ID vinyl tubing over the hose barb.
Содержание 6200VS-ECC
Страница 2: ...2 V3 15 22 This page intentionally left blank ...
Страница 12: ...12 V3 15 22 6200 8200VS Installation Diagrams ...