28
V3.15.22
Advanced Operation
CellarPro cooling systems can be programmed with advanced settings to
achieve more control over conditions inside the cellar. Conditions like
humidity, the Temperature Differential, and alarm settings all can be modified
for custom applications. To access the advanced settings, do the following:
Press the “Set” button and the “Down” button together at the same time,
and hold for three seconds. Then, use the “Up” or “Down” button to scroll to
the following screen:
HUMIDITY:
The factory preset for this setting is “3”.
If the humidity inside the cellar is too low, press the “Set”
button, then use the “Up” button until the desired setting is
reached. The recommended range for this setting is 0-6.
TEMPERATURE DIFFERENTIAL:
The factory preset for this setting is
“4”.
This setting determines the Temperature Differential and
therefore the temperature at which the cooling unit will cycle
on. The recommended setting is 4 unless using a bottle probe
in liquid
, in which case the recommended setting is 1.
HIGH TEMPERATURE ALARM:
The factory preset for this setting is “70”.
This setting designates the High temperature inside the cellar at
which the alarm is triggered. We recommend leaving this setting
at the factory preset.
LOW TEMPERATURE ALARM:
The factory preset for this setting is “45”.
This setting designates the Low temperature inside the cellar at
which the alarm is triggered. We recommend leaving this setting
at the factory preset.
ENERGY SAVINGS MODE DIFFERENTIAL:
The factory preset for this
setting is “4”.
This setting increases or decreases the Temperature Differential
for the Energy Savings Mode. The recommended range for this
setting is 2-4.