7
V3.15.22
PLEASE NOTE:
Our units were not designed for, and our warranty does not cover damage from, marine
exposure (within 5 miles of the ocean). In these environments, you will need an applied
coating, such as Insitu®, to protect against corrosion that is common in coastal regions.
With our (optional) compressor heater, all of our cooling units can be used in environments
down to 20°F, and with our (optional) fan cycling switch, all of our cooling units can be used
in environments down to -20°F.
・
H e a t
CellarPro cooling units are not designed to heat the cellar space, so if temperatures inside the
cellar drop below proper wine storage temperatures, the cooling unit cannot create heat inside
the cellar.
・
Insulation
CellarPro cooling units are designed to be
installed inside wine cellars that have
proper insulation, moisture barriers and
an airtight seal from the environment
outside the cellar. Interior walls and floor
should have a minimum of R-11
insulation, and a vapor barrier on the
warm side of the insulation. The ceiling
should have a minimum of R-19
insulation and a vapor barrier on the
warm side of the insulation. Doors also
should be insulated and tightly sealed
with weather stripping around the
perimeter of the door. Surface-mounted
fixtures
are
recommended
over
recessed lighting, which can allow air
to leak into the cellar.
It is important that all walls, joints, doors and windows, electrical outlets and/or
switches, pipes, vents and light fixtures be sealed to prevent air and moisture
from entering the cellar. If there is a leak in the cellar, the cooling unit will build
up excess condensation.
CellarPro 6200VS and 8200VS cooling units are equipped with a condensate
management system, which includes a stainless steel pan, a thermostatically-
controlled electric heating element, and an overflow drain at the rear of the cooling
unit.
We strongly recommend that the overflow drain line (shipped loose with the cooling
unit) be connected to the overflow drain (as shown in the installation section), and
that the cooling unit be mounted to tilt slightly backwards, so that any overflow