SL 102212
Page 14 | 1-855-235-5271
Initial Start-Up
When power is applied to the unit, the control will
briefly display all symbols, and the Compressor
symbol will be displayed (if unit is calling for cooling).
There may be a brief delay prior to the evaporator
and condenser fans turning on.
Normal System Cycle
After the Air Sensing Probe has reached the set
point (all units are shipped with the set point of
55°F and a differential of 4°F) the unit turns off. The
WHM is an adjustable feature which allows the
customer the convenience of managing the humidity
enhancement of their wine cellar. The WHM is one
of the many Customer Preference Selection features
which allow the customer the ability to fine tune the
controls. This feature is set to 0 when shipped but if
needed can be adjusted.
Anti Short Cycle
The Anti Short Cycle ensures that the unit will remain
off for a period of 3 minutes after the unit has reached
the set point to allow the pressure in the refrigeration
system to equalize prior to starting the compressor.
Anti Frost Cycle
The Anti Frost Cycle is a precautionary measure, as
icing or frosting of the coil does not occur during
normal operation. The system will go through an
anti frost cycle when the evaporator temperature
reaches 26°. During the Anti Frost cycle, the unit will
stop cooling and run the indoor fan to provide air
flow across the indoor coil, which will melt any frost
accumulation.
Air Sensing Probe Failure Protection
In the event that a Air Sensing Probe should fail,
the APST (Advance Product Safety Technology) will
automatically transition the Refrigeration Compressor
cycles to a pre-determined time series (based on
detailed laboratory testing), which will ensure that
the product is kept within the safe range.
SYSTEM OPERATION
Содержание SL Series
Страница 1: ......
Страница 15: ...www cellarcool com Page 13 NOTES ...
Страница 28: ...CellarCool 1738 E Alpine Ave Stockton CA 95205 1 855 235 5271 1 855 Cellar1 www cellarcool com ...