DISPLAY
LAYOUT
Compressor is on
Fan is on
Anti-Frost Cycle running
Alarm is present
°
F
°
F
View/Change Setpoint
Enter User Menu
Unlock Button
(
hold for 1 sec
)
Scroll Button
Change Setpoint
55
°
F
Power On/Off
(hold for 5 sec)
Scroll Button
Change Setpoint
Return to Previous
Menu
Magnum
9000 SPECIFICATIONS
Model
9000 H.E. Evaporator Unit
(Fan Coil Unit)
H.E.
Condenser
(Air-Cooled Condensing Unit)
Dimensions
Refrigerant
R-134a
Condensing Unit HP
1HP
Voltage Rating
120V (15-amp dedicated circuit required)
Weight (lbs)
96
64
Amps
9.37 Running Amp
Line Set
Liquid line 3/8” OD; Suction line 5/8” OD (less than 50 ft.), 3/4” (greater than 50 ft.)
Drain Line
3/4” ID CPVC
Installation
Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat
KDT- Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable), 24V - Customer supplied
Temp. Delta
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty
Two-year limited warranty (parts and labor)
BTU/h (60°F condenser air
intake temperature)
BTU/h (75°F condenser air
intake temperature)
BTU/h (85°F condenser air
intake temperature)
10985/11361
10711/11019
10145/10786
H.E. Condenser (Air-Cooled
Condensing Unit)
29.5”L x 30.9”W x 19.8”H
31.18"L x 10.75”W x 21.18"H
220V (15-amp dedicated circuit required)
LRA 20, RLA 4.25, FLA 4.89
Cellar Size
3000 cu. ft. *
Page 49