INSTALLING THE CONDENSING UNIT

Step 1: Select installation location

Before installing the outdoor unit, you must choose an appropriate 
location. The following are standards that will help you choose an 
appropriate location for the unit.

Proper installation locations meet the following standards:

Meets all suggested spatial requirements according to diagram

Good air circulation and ventilation

Firm and solid—the location can support the unit, is level, and will not vibrate

Protected from prolonged periods of direct sunlight or rain

Condensing unit is suggested to be mounted on concrete pad. Wall mounting is 

optional but will cause excess vibration.

DO NOT install unit in the following locations:

Near an obstacle that will block air inlets and outlets

Near a public street, crowded areas, or where noise from the unit will disturb others

Near animals or plants that will be harmed by hot air discharge

Near any source of combustible gas

In a location that is exposed to large amounts of dust

In a location exposed to a excessive amounts of salty air

In a closet or small room

Special Considerations For Cold Weather And Other Outdoor Conditions

If the unit is exposed to heavy wind:

 Install unit so that air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier in front of the unit to protect it 
from extremely heavy winds.

If the unit is frequently exposed to heavy rain or snow:

Build a shelter above the unit to protect it from the rain or snow. Be careful not to obstruct air flow around the unit. Unit should be 

elevated to prevent build up of debris and snow in front of fan. 

Step 2: Anchor outdoor unit

The outdoor unit can be anchored to the ground or to a wall-mounted bracket.

 Unit Mounting Dimensions

The following is a list of different outdoor unit sizes and the distance between their mounting feet. Prepare the 

installation base of the unit according to the dimensions

Outdoor Unit Dimensions (in.)

 

Mounting Dimensions

Distance A (in.)

Distance B (in.)

31.18"L x 10.75”D x 21.18"H

19.72”

10.71”

Page 42 

08/09/21

Содержание MAGNUM H.E.

Страница 1: ...MAGNUM H E OWNER S MANUAL NOTICE To activate the split system warranty the installing certified H AC R service tech must complete the split system warranty checklist and send back to CellarCool...

Страница 2: ...not responsible for printing or clerical errors CellarCool reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vi...

Страница 3: ...ary Troubleshooting Guide Maintenance Schedule Page 2 Page 3 Page 4 Receiving Inspecting The System Page 6 Page 7 Condensate Drain Pan Page 8 Page 9 Rear Blower Orientation Instructions Page 10 Top Bl...

Страница 4: ...zed refrigeration system designed for one purpose only to maintain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wine This system produces minimal in ce...

Страница 5: ...ou are REQUIRED to install a drain line to remove condensation from the evaporator unit 5 The warranty is not active until a warranty checklist has been received reviewed and approved 6 The system is...

Страница 6: ...he insulation is to conducting heat and the more consistent your wine cellar s temperature will be Using higher R values in insulation will lower your operating costs and unit run time R 13 is the rec...

Страница 7: ...eat away from the condensing unit is critical to the unit s performance and cannot be overstated As the system operates and cools a greater amount of heat is generated on the condensing side of the sy...

Страница 8: ...Magnum 12000 H E condensing unit depending on unit ordered 3 Verify that the square to round plenum box contains the following 1 Square to round plenum 8 10 16 x 1 2 steeldrillingscrews Pictured 9000...

Страница 9: ...t options Power supply knockout Bottle probe knockout Drain port 3 4 CPVC Interchangeable panels Display knockout Return air Supply air Line set knockout options Power supply knockout Display knockout...

Страница 10: ...N PAN Check local codes and regulations regarding the disposal of condensation for specific installation requirements A separate drain line will need to be installed Please see page 26 for more info P...

Страница 11: ...t for the flexible duct to prevent sags and bends Magnum 9000 and 12000 duct size 14 supply and return Register size 14 x 14 Filter size 14 x 14 MERV 4 Stretch out the duct to make a smoother interior...

Страница 12: ...upply panel oriented to the right If this is your desired orientation proceed to the installation instructions on page 23 2 To reorient the blower first remove the access panels on the rear and top of...

Страница 13: ...tate the blower to the rear configuration 4 Remove the six 6 screws securing the supply panel to the unit housing 5 Remove the supply panel REAR BLOWER ORIENTATION INSTRUCTIONS CONTINUED Page 11 08 09...

Страница 14: ...re blower to supply panel using the eight 8 screws removed earlier 9 Reattach top panel with the six 6 screws removed earlier Attach the panel which was formerly the rear panel on the right side of th...

Страница 15: ...top of the unit use the secondary foam fan bracket packaged with the unit pictured below The purpose of this piece of foam is to enable you to orient the blower so that the supply air duct faces upwar...

Страница 16: ...the eight 8 screws securing the blower to the supply panel 3 Remove the six 6 screws securing the supply panel to the unit housing TOP BLOWER ORIENTATION INSTRUCTIONS CONTINUED 4 Remove the panel Pag...

Страница 17: ...blower out through the rear access panel 6 Set the piece of foam shown on page 16 into the foam fan bracket on the bottom of the unit housing TOP BLOWER ORIENTATION INSTRUCTIONS CONTINUED Page 15 08...

Страница 18: ...in from the rear and set upright on the piece of foam NOTE Make sure that the blower motor is closest to the side access panel as shown above TOP BLOWER ORIENTATION INSTRUCTIONS CONTINUED BLOWER MOTO...

Страница 19: ...ews removed earlier 9 Attach the supply panel to the top of the unit using the six 6 screws removed earlier Then attach the blower to the panel using the eight 8 screws removed earlier TOP BLOWER ORIE...

Страница 20: ...e double sided tape on the flanges of the square to round plenum 2 Stick the plenum onto the supply panel NOTE Make sure that the corners of the square to round plenum do not block the airflow from th...

Страница 21: ...SQUARE TO ROUND PLENUM INSTALLATION CONTINUED 3 Secure the square to round plenum to the housing with the provided 10 16 x 1 2 steel drilling screws 4 Seal all seams with foil tape Page 19 08 09 21...

Страница 22: ...nough to extend from the ceiling joists to the screws located at the top corners of the evaporator unit s e l o h w e r c s e h t t u o g n i p p i r t s t n e v e r p o t e u q r o t f o s b l 8 o t...

Страница 23: ...stallation location 3 Route the bottle probe cable from the desired thermostat bottle location to the evaporator installation location 4 Route the drain line from a proper discharge location to the ev...

Страница 24: ...able inside of the evaporator unit 3 Connect the wires according to color red to red green to green and blue to blue Note The evaporator unit will not contain a yellow wire See next step for more info...

Страница 25: ...to the unit as shown in Figure 1 INSTALLING THE EVAPORATOR UNIT 12 Connect the end of the display cable labeled UNIT to the wire labeled UNIT coming from the controller box 13 Install the supplied pie...

Страница 26: ...er or deburring tool remove all burrs from the cut section of the pipe F F Oblique Rough Warped 90 CONNECTING THE LINESET 3 Flare pipe ends Proper flaring is essential to achieve an airtight seal a Af...

Страница 27: ...Using a spanner grip the nut on the unit tubing PIPING EXTENSION BEYOND FLARE FORM Outer Diameter of Pipe in A in Min Max 1 4 0 0275 0 05 3 8 0 04 0 063 0 04 0 07 0 078 0 086 0 078 0 094 Flare form P...

Страница 28: ...The Magnum evaporator unit accepts 3 4 CPVC tubing It is imperative that you use primer and glue to ensure there is a watertight seal between the tubing and all fittings All joints and connections sh...

Страница 29: ...as not been changed to 5 The factory setting allows the unit to run even if the EA alarm is tripped The alarm will be corrected when the water level inside the drip pan decreases and the float switch...

Страница 30: ...itting coming from the unit and the CPVC tube which will be connected to it Insert the a piece of CPVC tubing into the female fitting Route additional CPVC tubing to an appropriate discharge location...

Страница 31: ...le off to the side of the unit in your wine cellar with the probe level 5 To ensure a consistent temperature place bottle probe approximately three 3 feet away from the air output and not in the flow...

Страница 32: ...cket REMOTE DISPLAY INSTALLATION AND CONFIGURATION NOTE Cut hole in the location shown for routing the display cable Tools needed 5 16 drill bit 3 16 drill bit drywall saw level pencil What s included...

Страница 33: ...he four 4 provided drywall anchors into the drywall then tap them in with a hammer until they are flush with the wall 3 Place bracket against wall aligning screw holes with drywall anchors Insert the...

Страница 34: ...e labeled DISPLAY to the JST connector on the back of the display DIS PL AY JST connector NOTE Before you continue to Step 4 locate the area where the display will be mounted You may route the display...

Страница 35: ...oss 4 Cut along the perforated lines When finished remove template from wall INSTALLING THE EVAPORATOR 1 Locate the desired installation location 2 If utilizing an external or secondary drip tray ensu...

Страница 36: ...cking from the double sided tape on the flush mount bracket 6 Align magnets with previously drilled holes Make sure the cut out portion of the bracket circled below is on the bottom Press the bracket...

Страница 37: ...ace the display on the flush mount bracket as shown attaching the back of the display panel to the magnets on the mounting bracket Make sure that the alignment tab on the back of the display panel sit...

Страница 38: ...EVAPORATOR WIRING DIAGRAM KDT Page 36 08 09 21...

Страница 39: ...EVAPORATOR WIRING DIAGRAM 24V Page 37 08 09 21...

Страница 40: ...CONDENSING UNIT WIRING DIAGRAM Page 38 08 09 21...

Страница 41: ...n the system is installed with the condensing unit at a higher elevation than the coil Reverse oil return bend Oil saving bend Suction Line Evaporator Coil Within 16 of height Downward slope pitched t...

Страница 42: ...ems do not utilize a solenoid valve or low pressure switch which allows the system to run like a residential HVAC system A 24V communication cable must be ran between the condensing unit and the evapo...

Страница 43: ...condensing unit per electrical code 2 Remove electrical cover plate from unit 3 Connect wiring for 24V contactor communication cable L1 L2 and Ground as identified by terminal block label 4 Leave the...

Страница 44: ...combustible gas In a location that is exposed to large amounts of dust In a location exposed to a excessive amounts of salty air In a closet or small room Special Considerations For Cold Weather And...

Страница 45: ...ut on the end of eachexpansion bolt 5 Thread expansion bolts through holes in mounting brackets put mounting brackets in position and hammer expansion bolts into the wall 6 Check that the mounting bra...

Страница 46: ...ately 225 psi Open both high side and low side gauge manifold knobs SLOWLY at the same time to admit nitrogen into the system until the gauge manifold reads 225 psi then close gauge manifold knobs Let...

Страница 47: ...e port if necessary to achieve recommended subcooling Check the superheat at suction service valve on the condensing unit Adjust the TXV until the superheat is between 10 25 F at the service valve Aft...

Страница 48: ...equivalent Confirm that the control is displaying the correct temperature and that no alarms are present INSTALLING THE CONDENSING UNIT continued Finalizing the Installation Approximate Operating Pre...

Страница 49: ...mpressor Once the contactor relay is de energized the controller must wait five minutes before re energizing the relay This prevents the compressor from repeatedly turning off and on If the unit is ca...

Страница 50: ...safety feature that will prevent the condensing unit from cycling on and off within a short period of time During the anti short cycle the condensing unit will typically remain off for 5 7 minutes Se...

Страница 51: ...ft 3 4 greater than 50 ft Drain Line 3 4 ID CPVC Installation Condensing unit can be installed up to 100 line feet from the evaporator unit Thermostat KDT Advanced digital display 50 ft cable liquid...

Страница 52: ...sions Refrigerant R 134a Condensing Unit HP 1 5 HP Voltage Rating 120V 15 amp dedicated circuit required Weight lbs 96 84 Amps 9 37 Running Amp Line Set Liquid line 3 8 OD Suction line 5 8 OD less tha...

Страница 53: ...and adjust parameters such as setpoint Fon FOF etc SET To change the setpoint press the SET button When SEt is displayed on the screen press the SET button once more Use the UP and DOWN ARROW buttons...

Страница 54: ...undergoing an Anti Frost Cycle While the Anti Frost Cycle is running dEF will be displayed on the screen See System Operation page for further details FAN The evaporator fan is running ALARM The alarm...

Страница 55: ...dead clock battery will not affect the operation of your cooling unit The following alarm codes will not be displayed on the home screen However the alarm icon will be displayed in the event of an ala...

Страница 56: ...adjust this setting in the User Menu Fon fan on The fan on time is preset to zero minutes This keeps the relative humidity of the wine cellar at a stable level If however you wish to raise the relativ...

Страница 57: ...mer Service at 1 800 343 9463 Cellar temperature is too warm Possible cause Solution The temperature of the room to which the unit is exhausting has ex ceeded 110 F Intake temperature needs to drop be...

Страница 58: ...icon illuminated on the control the system is going through an Anti Frost Cycle No action is required 2 If the system is not maintaining the correct cellar temperature the evaporator coil may be dirty...

Страница 59: ...rm water 3 Ensure the condensing unit is free of debris and dust 4 Have a certified HVAC R technician service the condensing unit and clean the condenser coil Annually 1 Inspect outdoor condenser for...

Страница 60: ...and eye irritation They are harmful or fatal if ingested Wear protective gloves when handling pan tabs Wash thoroughly after handling If pan tabs make contact with eyes rinse cautiously with water for...

Страница 61: ...ccessories to enhance and customize your wine cooling unit Condensate Pump Kit The condensate pump kit automatically removes water that drips out of the evaporator unit s drain line The pump is contro...

Страница 62: ...ited Warranty If the Split Startup Checklist is approved Purchaser will be sent activation approval documents and will start receiving the benefits of the Limi ed Warranty throughout the warranty peri...

Страница 63: ...le receipted invoice or serial number which is evidence that the Product is within the Limited Warranty Period must be presented by the End User to CellarCool in order to obtain limited warranty servi...

Страница 64: ...arCool Customer Service to arrange for replacement under the warranty guidelines When a claim for warranty is submitted for a condenser skid the End User must purchase a new condenser skid from Cellar...

Страница 65: ...umentation to the customer to substantiate the finding This will include the Invoice from the Independent Certified H AC R Technician and the written report of the finding The Owner will become respon...

Страница 66: ...available Monday through Friday from 6 30 a m to 4 00 p m PST The Customer Service representative will be able to assist you with your questions and warranty information more effectively if you provid...

Страница 67: ...CellarCool 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www cellarcool com...

Отзывы: