9. Trouble shooting
Fault
Possible cause
Action
A. Pumps/forward drive/brushes will
not start
The machine is not connected to the
power source
The main switch is turned off
There has been a thermal cut-out
Connect the power
Switch the main switch to position ”I”
Check the frequency converter in
the electrics cabinet
B. Forward drive roller and brushes
are not rotating
The power supply to the motor for
the forward drive is interrupted
The V-belts/toothed belts are too
loose or damaged
A belt is broken
The forward drive roller, V-
belt/pulley is not fastened to the axel
See ”A”
Tighten/replace the belt (-s)
Replace the belts
Fasten them to the axel
C. The motor for forward
drive/brushes cuts out
The motor is overloaded; there can
be defective parts in the
transmission, or another blocking in
the machine.
Check if all visible machine parts
can spin free. If not, repair if
possible. Open the electrics cabinet
and reset the motor protecting
switch. Wait 10 min. and then start
the machine.
Содержание IS-250
Страница 1: ...1 29 Users guide Ceetec IS 250...
Страница 19: ...19 29 13 Spare parts overview Picture A The machine seen from above...
Страница 20: ...20 29 Picture B The machine seen from below...
Страница 21: ...21 29 Picture C The machine seen from the side...
Страница 22: ...22 29 Picture D The lid of the machine...
Страница 24: ...24 29 Picture G Demounting the vertical sanding heads Picture H Adjusting the vertically sanding heads...
Страница 25: ...25 29 Picture I Adjusting the horizontally sanding heads Picture J Adjusting the Counter pressure roller...
Страница 26: ...26 29 Picture K Steering board Picture L Changing the sanding strips...
Страница 27: ...27 29 Picture M Changing the sanding strips Picture N Reversing of circulation direction on sanding head...
Страница 29: ...29 29 Picture Q Reversing of circulation direction on sanding head...