background image

Cecomp

®

 Low-Voltage Powered Digital Pressure Gauges with Selectable Units 

F16AD, F16ADN

cecomp.com

1220 American Way Libertyville, IL 60048
Phone: 

800-942-0315

 

Fax: 800-949-7502

© 02-12

Ranges and Resolution

See table below. Select range and default engineering units. 
Consult factory for special engineering units.
Units may be changed to any listed under the same sensor range.
Resolution is fixed and limited to available display digits.

Accuracy

Includes linearity, hysteresis, repeatability
Standard:  ±0.25% of full scale ±1 least significant digit

HA

 option:  ±0.1% FS ±1 LSD, see table below for availability

Display

3 readings per second nominal display update rate
4 digit LCD, 0.5" H and 5 character 0.25" H alphanumeric

BL

: Red LED backlight on when gauge is on

Power

8-24 VAC 50/60 Hz or 9-32 VDC

AD

Approximately 5 mA

ADBL

Approximately 80 mA

3 ft long, 2-conductor 22 AWG cable
All models are designed for continuous operation
Order optional WMPSK 115V/12 VDC wall mount power supply kit.

Controls and Functions

Front button turns gauge on or off, zeros gauge reference gauges, 
and cycles through min/max functions
Internal buttons for engineering unit selection, auto shutoff time, 
min/max setup, calibration. Pass code protected setup & calibration.

Min/Max Functions

Minimum and maximum readings stored 3 times per second
Front button cycles through min display, max display, clear
Configurable for min only, max only, min/max, or none
Configure to clear or retain min/max values at power off

 

±0.25% Test Gauge Accuracy

 

316 Stainless Steel Wetted Parts

 

Minimum, Maximum, Zero Functions

 

Selectable Units

 

Low Voltage Powered

BSOLUTE

ROCESS

NSTRUMENTS, Inc.

Division of

Calibration

Pass code protected calibration
Non-interactive zero, span, and linearity, ±10% of range

Weight

Gauge: 9 ounces (approximately)
Shipping: 1 pound (approximately)

Housing

F16AD

: Extruded aluminum case, epoxy powder coated, ABS/ 

polycarbonate bezel (aluminum bezel optional), front and rear 
gaskets, polycarbonate label

F16ADN

: ABS/polycarbonate NEMA 4X case, rear gasket, polycar-

bonate label

Connection and Material

1/4" NPT male fitting, 316L stainless steel
All wetted parts are 316L stainless steel

Overpressure, Burst, Vacuum

Ranges using 3000 psig sensor:  5000 psig
Ranges using 5000 psig sensor:  7500 psig
All others: 

2 X pressure range

3000 psi, 5000 psi, and 4 digit ranges 112.5% full scale out-of-
range display: 1– – – or I –.–.–.–

4 X sensor burst pressure rating, or 10,000 psi, whichever is less

Vacuum service: ±15 psig, 15 psig, 30 psia, 100 psig, 100 psia, 
200 psig sensors.
Under-range display (non-vacuum sensors): –Err

Environmental

Storage temperature: 

–40 to 203°F (–40 to 95°C)

Operating temperature: 

–4 to 185°F (–20 to 85°C)

Compensated temperature: 

32 to 158°F (0 to 70°C)

F16AD

Quick Link

cecomp.com/ad

Made

in

U S A

★ ★ ★ ★ ★ ★

★ ★ ★ ★ ★

★ ★ ★ ★ ★ ★

★ ★ ★ ★ ★

★ ★ ★ ★ ★ ★

★ ★ ★ ★ ★

★ ★ ★ ★ ★ ★

★ ★ ★ ★ ★

★ ★ ★ ★ ★ ★

How to Specify

Type

F16AD

 range - options

Standard housing

F16ADBL

 range - options

Standard housing, 

backlit display

F16ADN

 range - options

NEMA 4X housing

F16ADNBL

 range - options

NEMA 4X housing, 

backlit display

Example: 

F16ADBL100PSIG-HA

 

Low voltage powered, backlit display, 0-100 psig, high 

 accuracy

Sensor Ranges and Engineering Units  

‡ -HA option not available

3 psig 

Res

15 psig vac 

Res

30 psia 

Res

–15V100psig 

Res

300 psig

Res

3PSIG

.001

100KPAVAC

.1

2KGCMA

.001

–15V100PSIG

.1

300PSIG

.1

6INHGG

.001

0.1MPAVAC

.0001

2ATMA

.001

–30INHG/100PSIG

.1

610INHGG

.1

85INH2OG

.1

1BARVAC

.001

30 psig

Res

–30V200INHGG

.1

4800ZING

1

50ZING

.01

1KGCMVAC

.01

30PSIG

.01

–400V2770INH2OG

1

700FTH2O

.1

210GCMG

.1

1ATMVAC

.001

60INHGG

.01

–240V1600ZING

1

2000KPAG

1

150MMHGG

.1

15 psig

Res

850INH2OG

1

–760V5200MMHGG

1

2MPAG

.001

150TORRG

.1

15PSIG

.01

480ZING

.1

–760V5200TORRG

1

20BARG

.01

200MBARG

.1

30INHGG

.01

2100GCMG

1

–100V700KPAG

1

20KGCMG

.01

200CMH2OG

.1

400INH2OG

.1

1600MMHGG

1

–0.1V0.7MPAG

.001

20ATMG

.01

2000MMH2OG

1

240ZING

.1

1600TORRG

1

–1V7BARG

.01

500 psig

Res

7FTH2O

.001

1000GCMG 

1

2000MBARG

1

–1V7KGCMG

.01

500PSIG

.1

20KPAG

.01

760MMHGG

.1

2100CMH2OG

1

–1V7ATMG

.01

1020INHGG

1

5 psig

Res

760TORRG

.1

70FTH2O

.01

100 psig

Res

1150FTH2O

1

5PSIG

.001

1000MBARG

1

200KPAG

.1

100PSIG

.1

3500KPAG

1

10INHGG

.01

1000CMH2OG

1

0.2MPAG

.0001

200INHGG

.1

3.5MPAG

.001

140INH2OG

.1

35FTH2O

.01

2BARG

.001

2770INH2OG

1

35BARG

.01

80ZING

.1

100KPAG

.1

2KGCMG

.001

1600ZING

1

35KGCMG

.01

350GCMG

.1

0.1MPAG

.0001

2ATMG

.001

7000GCMG

1

35ATMG

.01

260MMHGG

.1

1BARG

1

60 psig

Res

5200MMHGG

1

1000 psig

Res

260TORRG

.1

1KGCMG

1

60PSIG

.01

5200TORRG

1

1000PSIG

1

350MBARG

.1

1ATMG

1

120INHGG

.1

7000MBARG

1

2040INHGG

1

350CMH2OG

.1

±15 psig 

Res

1660INH2OG

1

7000CMH2OG

1

2300FTH2O

1

3500MMH2OG

1

±15PSIG

.01

960ZING

1

230FTH2O

.1

7000KPAG

1

12FTH2O

.01

–30INHG/15PSIG

.01

4200GCMG

1

700KPAG

.1

7MPAG

.0001

35KPAG

.01

±30INHGG

.01

3100MMHGG

1

0.7MPAG

.0001

70BARG

.01

15 psia 

Res

±400INH2OG

1

3100TORRG

1

7BARG

.001

70KGCMG

.01

15PSIA

.01

±240ZING

.1

4100MBARG

1

7KGCMG

.001

70ATMG

.01

30INHGA

.01

±1000GCMG

1

4200CMH2OG

1

7ATMG

.001

2000 psig

Res

400INH2OA

.1

±760MMHGG

1

140FTH2O

.1

–15V200 psig 

Res

2000PSIG

1

240ZINA

.1

±760TORRG

1

400KPAG

.1

–15V200PSIG

.1

4070INHGG

1

1000GCMA

1

±1000MBAR

1

0.4MPAG

.0001

–30INHG/200PSIG

.1

4600FTH2O

1

760MMHGA

.1

±1000CMH2OG

1

4BARG

.001

–30V400INHGG

.1

14MPAG

.01

760TORRA

.1

±100KPAG

.1

4KGCMG

.001

–400V5500INH2OG

1

140BARG

.1

1000MBARA

1

±0.1MPAG

.0001

4ATMG

.001

–240V3200ZING

1

140KGCMG

.1

1000CMH2OA

1

±1BARG

.001

100 psia 

Res

–100V1400KPAG

1

140ATMG

.1

100KPAA

.1

±1KGCMG

.001

100PSIA

.1

–0.1V1.4MPAG

.001

3000 psig

Res

0.1MPAA

.0001

±1ATMG

.001

200INHGA

.1

–1V14BARG

.01

3000PSIG

1

1BARA

.001

30 psia 

Res

2770INH2OA

1

–1V14KGCMG

.01

6100INHGG

1

1KGCMA

.001

30PSIA

.01

1600ZINA

1

–1V 14ATMG

.01

6900FTH2O

1

1ATMA

.001

60INHGA

.01

7000GCMA

1

200 psig

Res

20MPAG

.01

15 psig vac 

Res

850INH2OA

1

5200MMHGA

1

200PSIG

.1

200BARG

.1

15PSIVAC

.01

480ZINA

.1

5200TORRA

1

400INHGG

.1

200KGCMG

.1

30INHGVAC

.01

2100GCMA

1

7000MBARA

1

5500INH2OG

1

200ATMG

.1

400INH2OVAC

.1

1600MMHGA

1

7000CMH2OA

1

3200ZING

1

5000 psig

Res

240ZINVAC

.1

1600TORRA

1

700KPAA

.1

480FTH2O

.1

5000PSIG

1

1000GCMVAC

1

2000MBARA

1

0.7MPAA

.0001

1400KPAG

1

35MPAG

.01

760MMHGVAC

.1

2100CMH2OA

1

7BARA

.001

1.4MPAG

.001

350BARG

.1

760TORRVAC

.1

200KPAA

.1

7KGCMA

.001

14BARG

.01

350KGCMG

.1

1000MBARVAC

1

0.2MPAA

.0001

7ATMA

.001

14KGCMG

.01

340ATMG

.1

1000CMH2OVAC

1

2BARA

.001

14ATMG

.01

Options

—add to end of model number

HA

High accuracy, ±0.1% FS ±1 LSD. Not available with 3 
psi, bipolar, absolute, or vacuum sensors, and some 3.5 
digit  display ranges. See table at left for availability.

PM

Panel mount, 4.1" x 4.1". Not avail. with NEMA models.

MC

Metal front cover. Not available with NEMA models.

CC

Moisture resistant circuit board conformal coating

TP

Top gauge port. Not available with NEMA models.

Accessories

—order separately

WMPSK

Wall mount power supply kit, 115 VAC/12 VDC

RB

Protective rubber boot. Not avail. with NEMA models.

CD

Calibration data; 5 test points and date

NC

NIST traceability documentation, 5 points and date

F16ADN

 

psi = PSI

 

inHg = INHG

 oz/in

2

 = ZIN

 inH

2

O = INH2O

 ftH

2

O = FTH2O

  mmHg = MMHG

 

torr = TORR

 mmH

2

O = MMH2O

 kg/cm

2

 = KGCM

 g/cm

2

 = GCM

 

kPa = KPA

 

MPa = MPA

  mbar = MBAR
 

bar = BAR

 cmH

2

O = CMH2O

 

atm = ATM

G = gauge reference pressure

VAC = gauge reference vacuum

A = absolute reference

If vacuum gauge requires a minus sign, please specify.
The range code indicates the gauge’s default range.

 

Engineering 

units may be changed to any of those listed under the same sensor 
range. The listed ranges are rounded off.  

Range

—see table at left

MOD-TRONIC Instruments 

·

 

Brampton, ON 

· 

905-457-6322 or 1-800-794-5883 

·

 

[email protected] 

· 

www.mod-tronic.com

 

Отзывы: