NHV UL
Ugolini spa
7
ENGLISH
5. 3 CLEANING AND SANITIZING
PROCEDURES
1
- Cleaning and sanitizing of the dispenser are
recommended to guarantee the conservation of the best
product taste and the highest unit efficiency. This section
is a procedural guideline only and is subject to the
requirements of the local Health Authorities.
2 - Prior to the disassembly and cleaning, the machine must
be emptied of product. To do this proceed as follows:
- set the power switch to I position
- set mixer/refrigeration switch(es) to I position (Soft Drink
mode)
- place a pail under each faucet and drain all product from
bowls
- set all control switches to the 0 position.
5. 3. 1 DISASSEMBLY
1 - Remove cover from the bowl.
2 - Remove the bowl by lifting its faucet side up and off the
fastening hooks (see figure 5) and slide it out (see figure
6).
figure 5
figure 6
3 - Slide the outer spiral out (see figure 7) and then the inside
auger. Frequently remove the rear seal by sqeezing it to
break the suction grip (see figure 8).
figure 7
figure 8
ATTENTION
Before any disassembly and/or cleaning procedure
make sure that the dispenser is disconnected from its
power source.