background image

MODEL NO:

JAVA GIANT 2 (USA & CANADA)

JAVA GIANT 2 (USA & CANADA)

PHASE:

1 PHASE

1 PHASE

1 PHASE

1 PHASE

3 PHASE

VOLTS:

120

230

230

230

230

TOTAL 

KW

1.7

6

9

18

18

NO. OF 

HEATERS

1

3

3

3

3

AMPS

15

26

39

78

45

HZ.

60

60

60

60

60

RECEPTACLE

NEMA

L-5-15

L6-30R

HARDWIRED

HARDWIRED

HARDWIRED

CIRCUIT 

BREAKER

15A

30A

50A

100A

60A

 ELECTRICAL SPECIFICATIONS

UNITS OVER 30 AMPS MUST BE HARDWIRED.  CORDS NOT SUPPLIED.   FOR ALTERNATIVE WIRING METHODS, SEE HEATER POWER WIRING DIAGRAM.

MODEL NO:

JAVA GIANT 2 (USA & CANADA)

JAVA GIANT 3 (USA & CANADA)

WIDTH

IN

14.125

20.375

DEPTH

IN

24.25

24.25

HIGHT

IN

40.5

40.25

HOPPERS

QTY   LB. COFFEE

2        5.25

3         5.25

TANK

GAL.

7.5

10.5

ART AREA

IN

13.75 x 16.75

20 x 16.75

SHIPPING 

WEIGHT LB.

155

195

MECHANICAL SPECIFICATIONS

Height:  add 4" for legs;     Depth:  add 2"  for clearance for waterline hookup;

FAST START UP PROCEDURE

Water Inlet Connection

This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction.  In addition:

1.  A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for 

cleaning underneath.

2. An approved back flow prevention device, such as a double check valve to be installed between the machine and the water supply.

The JAVA GIANT 2/3 (USA and CANADA)  is equipped with a 

3/8" 

Flare Water Inlet Fitting

.

HIGHLY RECOMMENDED: 
A WATER SHUT-OFF VALVE and A WATER FILTER, preferably a combination Charcoal/Phosphate Filter, to remove odors and inhibit lime and

 

scale 

build up in the machine.   Note:  In areas with extremely hard water, a water softener must be installed in order to prevent a malfunctioning of the 
equipment and in order not to void the warranty. 

STARTUP PROCEDURE

Caution:   Make sure that the Heater Switch, located behind right hopper with door opened,  is in the OFF position.

1. JAVA GIANT2/3 (USA & CANADA)  - Connect the 

3/8" dia

 copper waterline to the 

3/8" flare

 water inlet fitting of the valve.

2. Plug the power cord into a proper receptacle.

3. Activate the 

Power Switch

 (Toggle Up). The door display panel and the green dispense buttons will light up and the

 

tank will start filling. 

    Allow approximately

 4-6

 minutes for the tank to fill.

4. Activate the 

Heater Switch

.   Allow approximately 20-30 minutes for the water to reach a preset temperature of 195°F. 

    The heat up time will depend on the water inlet temperature, the input voltage and the wattage of the elements in the machine.

5. Place decanter under nozzle and press dispense switch. The machine will dispense water at the rate of 4 oz. per second. 

    Repeat it several times for each dispense switch to check for consistent output. 

6. While the tank is heating up, remove the hoppers, load them with products and reposition them back in the machine.  

    When the heater light  goes OFF, the tank has reached its brew temperature and the machine is ready to dispense Coffee.

Содержание JAVA GIANT 2

Страница 1: ......

Страница 2: ...re Water Inlet Fitting HIGHLY RECOMMENDED A WATER SHUT OFF VALVE and A WATER FILTER preferably a combination Charcoal Phosphate Filter to remove odors and inhibit lime and scale build up in the machin...

Страница 3: ...TRAY CUP DRAIN PLUG URN STAND DRAIN HOSE 5 I D URN STAND GRILL DRAIN DRIP TRAY DRIP TRAY GRILL CUP PULL DOWN TRAY URN STAND PULL DOWN TRAY 3 OPTIONS DRAIN HOOK UP FOR JAVA P811A 10 32 x 3 8 SCREW DRAI...

Страница 4: ...a time CLOCKWISE to decrease water flow or COUNTERCLOCKWISE to increase water flow 4 Check water flow output after each 1 4 turn P510A C CLIP CD77A SOCKET MIXING CHAMBER ASSEMBLY K600Q JAVA GIANT2 3 H...

Страница 5: ...The Gram Throw is factory preset between 6 and 7 1 8 gr oz for the JAVA machines Drink or product strength can be changed by adjusting the Auger Motor RPM see knobs on inside door panel The water flow...

Страница 6: ...ALL HAND UP BRACKET FOR FILLER HOSE 1 LOOSEN THE TWO TOP SCREWS 2 PULL OUT RIGHT SIDE PANEL ABOUT 1 2 BY THE LOUVERS 3 SLIDE IN HOSE HANGER AS SHOWN 4 TIGHTEN LOOSENED SCREW HOSE HANGER RV53A WIRE HOO...

Страница 7: ...TCH DRAIN 9 5 6 5 DECANTER 1 2 GAL 3 1 75 PULL DOWN TRAY UP POSITION 11 25 HEATER SWITCH 6 FRONT VIEW LABEL AREA URN STAND WITH DRAIN TROUGH 203 8 3 FOR HEATER FRONT VIEW LABEL AREA PILOT LIGHT DRIP T...

Страница 8: ...PONENTS JAVA JR PC CANADA 22 4 HOPPER ASS Y P DOOR LATCH TIMER KNOB COVER RS27A FACIA BOTTOM CAP FRONT SE64A FACIA BOTTOM CAP REAR SE63A GRILL TRAY W DRAIN DECANTER 1 2 GAL POTENTIOMETERS 2 PRODUCT ST...

Страница 9: ...THERMOSTAT 120V HI LIMIT GASKET SILICONE BUTT SPLICED TANK WELDMENT ASS Y JAVA 2 JAVA 3 GROMMET 593 ID COFFEE JAVA 2 JAVA 3 GROMMET 466 ID WATER JAVA 2 JAVA 3 DISPENSE VALVE COFFEE JAVA 2 JAVA 3 DISP...

Страница 10: ...Z DRAWINGS ND000 ND80A D JAVA MAN dwg 07 08 2002 09 10 56 AM 1 8 12598 1 9 6 5 3 2 13 14 15 16 17 18 20 21 38 34 35 36 44 45 25 27 28 31 19 43 41 40 37 10 7 8 4 32 22 23 33 24 11 12 42 26 39 29 30...

Страница 11: ...OSE 18 M172S M172S 1 4 LEGS 1 FEET M042A SET OF 4 SUPPLY BOTH 19 RQ64A 1 SHELF JAVA GIANT 2 ONLY 20 RQ78A RW41A 1 GRILL 21 RQ16A RW40A 1 METAL TRAY PAN 22 C165A C165A 1 HEATER LIGHT RED 23 CD77A CD77A...

Страница 12: ...2 4 1 3 2 4 COFFEE 1 3 1 2 4 3 2 4 1 3 2 4 1 3 DECAF L3 L2 L1 120V GND 220V FUSE POT POT L1 N GND G RED BLK WATER INLET VALVE WHT BLU YEL GRN...

Страница 13: ...Z DRAWINGS NE000 ne52a dwg 07 08 2002 09 29 34 AM 1 0 983246 CECILWARE CORPORATION...

Страница 14: ...Z DRAWINGS NE000 NE60A dwg 07 08 2002 09 18 04 AM 1 0 983282 CECILWARE CORPORATION...

Страница 15: ...Z DRAWINGS NE000 NE61A dwg 07 08 2002 09 18 46 AM 1 1 51271...

Страница 16: ...WIRE W PUSH ON TERMINAL IS CONNECTED TO CONTACTOR L3 HARDWIRED L1 L3 L2 CONTACTOR G GROUND TERMINAL RED BLUE BLK T1 T3 T2 CONNECT L1 L2 GROUND BLOCK L1 L3 L2 CONTACTOR G GROUND TERMINAL RED BLUE BLK T...

Страница 17: ...BLK WATER INLET VALVE WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER RED WHT BLU YEL GRN...