Cecilware BC2-IT
BC302-IT Скачать руководство пользователя страница 7

 

7

Brewing State 

BREWING    DDD K 

MM:SS    HH:MMP 

Description

 – This screen is displayed when a Brew Cycle is in progress.  The time remaining in the 

Brew Cycle is displayed in the lower left-hand corner of the screen (depicted as “MM:SS”). The Brew 
Key LED will blink in this state.  The Main Warmer is automatically activated upon entry into this state.  
The Brewing parameters of Brew Size, Dilution, Pre-Infusion, Pulse Brew, and Drip Time are utilized in 
this state.  Refer to the Service Mode Descriptions for more information on Brew parameters. 
 
Pressing the Brew Key or the Cancel Key while in the Brewing State will abort the Brew Cycle and 
revert the system to the Ready State. 
  

Brew Fill Constant Calibration State

 

-- 

Description

 

 The Brew Fill Constant Calibration State is entered from the Heating State or the Ready 

State by simultaneously pressing the [Down Arrow] Key and the Brew Key.  The system will 
immediately energize the Dump Solenoid (and dispense hot water) for exactly 10 seconds.  The 
required Brew Fill Constant can be verified by dividing the volume of hot water dispensed by 10 thus 
yielding the actual Brew Fill Constant in ounces per second. 

Dilution Fill Constant Calibration State 

--- 

Description –

 The Dilution Fill Constant Calibration State is entered from the Heating State or the 

Ready State by simultaneously pressing the [Up Arrow] Key and the Brew Key.  The system will 
immediately energize the Dilution Solenoid (and dispense hot water) for exactly 10 seconds.  The 
required Dilution Fill Constant can be verified by dividing the volume of hot water dispensed by 10 thus 
yielding the actual Dilution Fill Constant in ounces per second. 
 

Warmers 

--- 

Description –

 The warmers are generally controlled manually via the Warmer Keys on the keypad.  

The only situation when this is not the case is during a Brewing Cycle.  The Main Warmer is 
automatically turned ON when the system enters the Brewing State.   Each Warmer has an optional 
timer, power level, audible alarm, and power reduction feature associated with it.  The Warmer Timer is 
particularly useful to indicate when a brew has become stale.  Refer to the Service Mode Descriptions 
for more information on Warmer options. 

Real-Time-Clock 

--- 

Description

 

 The Real-Time-Clock (RTC) allows the system to automatically turn ON at a specified 

time (usually in the morning) and turn OFF at a specified time (usually at night).  The RTC also has 
separate settings for weekdays and weekends.  This feature eliminates the wait associated with 
heating up the reservoir tank every morning.

  

Refer to the Service Mode Descriptions for more 

information on Real-Time-Clock parameters. 

 
 
 
 
 
 
 

 
 
 
 
 

Содержание BC2-IT BC302-IT

Страница 1: ...0th Avenue Long Island City NY 11105 TEL 718 932 1414 FAX 718 932 7860 MODELS Single BC301 IT Twin BC2 IT BC302 IT MANUAL Specifications Installation Operating Instructions Programming Instructions Ca...

Страница 2: ...the tank and the Warmers The Brewer will automatically start filling the tank then it will start to heat up the Water in the tank until it reaches the proper preset temperature 200 F About 20 minutes...

Страница 3: ...totalizers for product marketing information and inventory control 7 Advanced system diagnostics that continuously monitor the status of valves sensors and heaters to ensure proper operation and aid i...

Страница 4: ...h as a double check valve to be installed between Brewer and water supply WATER CONNECTION The Brewer comes equipped with a inch compression water inlet fitting located in the back Use a inch copper t...

Страница 5: ...ol brewing Service Mode This mode becomes active when the hidden keys under the Cecilware Logo located on the upper left hand side of the keypad and the first letter of the Model Name located on the u...

Страница 6: ...displayed during the initial filling of the water tank first fill Once the water in the reservoir tank has reached the appropriate fill level this screen is retired Heating State HEATING DDD K TTTF H...

Страница 7: ...e Dilution Fill Constant Calibration State is entered from the Heating State or the Ready State by simultaneously pressing the Up Arrow Key and the Brew Key The system will immediately energize the Di...

Страница 8: ...to easily start a Brew Cycle while preventing unauthorized users from doing the same The presence of the KL symbol on the screen in Normal Mode indicates the status of KeyLock see Normal Mode Descript...

Страница 9: ...for any water remaining in the funnel to drain out DILUTION DILUTION 36 ON OFF Description The Dilution feature gives the user the ability to add hot water directly to the brew without passing through...

Страница 10: ...maximum length of time a brew remains fresh while being warmed Once the Warmer Timer has expired an alarm is generated An alarm consists of a blinking warmer LED and optionally the audible alarm buzze...

Страница 11: ...ust set the systems Real Time Clock Minutes placeholder ADJUST HOURS ADJUST HOURS DAY MM SS Description The Adjust Hours function allows the user to adjust set the systems Real Time Clock Hours placeh...

Страница 12: ...ntrol Card or Water Temperature Sensor OVER FLOW SYSTEM ERROR OVER FLOW Description This screen is displayed and the unit is disabled when the Over Flow Level Sensor is detecting the presence of water...

Страница 13: ...ASS Y 6 V210Q 1 V210Q 2 FUNNEL ASS Y BLACK 7 SF74Q 1 SC81Q 1 TANK WELDMENT ASS Y 8 R615A 1 SC86A 1 BASE WARMER COVER 9 G108A 1 G108A 2 WARMER ELEMENT 10 M090A 2 M090A 4 GROMMET F HEAT SHIELD 11 U485A...

Страница 14: ...83A 1 M483A 2 SILICONE HOSE 312 ID x 7 L 11 K671Q M197A 1 1 K671Q M197A 2 2 SPRAY HEAD FITTING ASS Y WITH RUBER WASHER 12 SD06Q E107A K668A 1 1 1 SD06Q E107A K668A 2 2 2 SPRAY HEAD BASE ASS Y SPRAY HE...

Страница 15: ...QTY P N BC2 IT BC302 IT QTY DESCRIPTION 1 L069A 1 L069A 1 POWER SWITCH 2 CD257 1 CD257 1 WATER INLET VALVE 3 B083A 1 B083A 1 TERMINAL BLOCK 4 CE202 1 CE202 1 POWER CORD 5 C396Q 1 C396Q 1 FUSE HOLDER A...

Страница 16: ...m of 3 min in the sanitizing solution Let all sanitized parts drain and dry naturally DO NOT WIPE THEM DRY Before using the sanitized unit or parts with food stuffs rinse all parts thoroughly with wat...

Страница 17: ...b Too much water in tank c Spray Head Fitting is clogged d Water Valve blocked by scales a Replace Water Dispense Valve b Dispense some water from tank c Clean Spray Head Fitting d Replace or clean V...

Страница 18: ...CD window Check the probe as follows Turn on the power from touchpad and water supply Check inside the tank to make sure the water is not touching the Probe Pull the wire and terminal out of the Probe...

Страница 19: ...GLE DISPENSE VALVE is factory adjusted to dispense 0 5 oz sec of water during the brew cycle spray duration b The DOUBLE DILUTION DISPENSE VALVE is factory adjusted on both sides to dispense 0 22 oz s...

Страница 20: ...6 8 12 14 J2 21 17 19 22 18 20 120VAC THERMISTOR L671A L2 N L1 TO SAFETY RELAY TO J3 PIN 3 TRIAC L623A 40A MT2 20 GA MT1 G 16 GA 20 GA TO FUSE 16 GA TO HEATER P5 KEYS WARM WARM PWR BERG CONNECT0RS P2...

Страница 21: ...MT2 G 7 6 T1 CH82A 120VAC 8VAC FUSE 6 AMP 17 18 18 17 SAFETY RELAY L553A K2 4 2 K1 3 1 100W 5 4 3 2 B190A SAFETY RELAY 10 9 1 3 2 4 5 7 6 8 13 14 11 12 15 16 1 10 1 3 5 7 2 4 6 8 13 11 9 15 14 12 16...

Отзывы: