ERROR MODE 

 

Description – The main function of Error Mode is report any system malfunctions and to disable the 
unit The system must be “powered down” using the Power Key located on the membrane keypad 
to reset any reported error

 

KEYPAD 

! SYSTEM ERROR ! 

KEYPAD 

Description

 – This screen is displayed and the unit is disabled when a key-press is detected during 

the initial application of power to the system.  This test is 

not

 performed during a Power Key 

initiated “power-on” sequence. 
Possible Causes 

– Membrane Keypad or someone depressing a key while applying power to the 

system 
110/220VAC ON 

! SYSTEM ERROR ! 

110/220VAC ON 

Description – This screen is displayed and the unit is disabled when line voltage is detected before 
the Safety Relay is energized.   
Possible Causes – Wiring or Safety Relay 

110/220VAC OFF 

! SYSTEM ERROR ! 

110/220VAC OFF 

Description – This screen is displayed and the unit is disabled when line voltage is 

not

 detected 

after the Safety Relay is energized.   
Possible Causes – Wiring, Fuse, High Temp Limit Switch, Control Card, or Safety Relay 

HIGH WATER TEMP 

! SYSTEM ERROR ! 

HIGH WATER TEMP 

Description – This screen is displayed and the unit is disabled when the present water temperature 
is sensed as being higher than 208 °F. 
Possible Causes – Wiring, Power Triac, Control Card, or Water Temperature Sensor 

OVER FLOW 

! SYSTEM ERROR ! 

OVER FLOW 

Description – This screen is displayed and the unit is disabled when the Over Flow Level Sensor is 
detecting the presence of water. 
Possible Causes – Wiring, Fill Solenoid, Control Card or Level Sensor 

NO FILL RESPONSE 

! SYSTEM ERROR ! 

NO FILL RESPONSE 

Description – This screen is displayed and the unit is disabled when the Fill Solenoid has been 
continuously energized (open & filling) for more than 15 minutes during the 

first fill

 or more than 30 

seconds thereafter. 
Possible Causes – Water Supply is turned off, Wiring, Control Card, Fill Solenoid, or Level Sensor 

NO TEMP RESPONSE 

! SYSTEM ERROR ! 

NO TEMP RESPONSE 

Description – This screen is displayed and the unit is disabled when the Water Heater has been 
continuously energized (heating) for more than 45 minutes. 
Possible Causes – Wiring, Control Card, Water Temperature Sensor, Power Triac, or Water Heater 

DUMP #1 CLOSED 

! SYSTEM ERROR ! 

DUMP #1 CLOSED 

Description – This screen is displayed and the unit is disabled when the system has been brewing 
(dispensing) for more than one minute and the Level Sensor has not sensed the absence of water.  
Possible Causes – Wiring, Control Card, or Dump Solenoid. 

TEMP SENSOR 

! SYSTEM ERROR ! 

TEMP SENSOR 

Description – This screen is displayed and the system is shut down when the Water Temperature 
Sensor is detecting an invalid (below 32°F or above 220°F) water temperature. 
Possible Causes – Wiring, Control Card, or Temperature Sensor. 

Содержание BC2-IT BC302-IT

Страница 1: ...0th Avenue Long Island City NY 11105 TEL 718 932 1414 FAX 718 932 7860 MODELS Single BC301 IT Twin BC2 IT BC302 IT MANUAL Specifications Installation Operating Instructions Programming Instructions Ca...

Страница 2: ...the tank and the Warmers The Brewer will automatically start filling the tank then it will start to heat up the Water in the tank until it reaches the proper preset temperature 200 F About 20 minutes...

Страница 3: ...totalizers for product marketing information and inventory control 7 Advanced system diagnostics that continuously monitor the status of valves sensors and heaters to ensure proper operation and aid i...

Страница 4: ...h as a double check valve to be installed between Brewer and water supply WATER CONNECTION The Brewer comes equipped with a inch compression water inlet fitting located in the back Use a inch copper t...

Страница 5: ...ol brewing Service Mode This mode becomes active when the hidden keys under the Cecilware Logo located on the upper left hand side of the keypad and the first letter of the Model Name located on the u...

Страница 6: ...displayed during the initial filling of the water tank first fill Once the water in the reservoir tank has reached the appropriate fill level this screen is retired Heating State HEATING DDD K TTTF H...

Страница 7: ...e Dilution Fill Constant Calibration State is entered from the Heating State or the Ready State by simultaneously pressing the Up Arrow Key and the Brew Key The system will immediately energize the Di...

Страница 8: ...to easily start a Brew Cycle while preventing unauthorized users from doing the same The presence of the KL symbol on the screen in Normal Mode indicates the status of KeyLock see Normal Mode Descript...

Страница 9: ...for any water remaining in the funnel to drain out DILUTION DILUTION 36 ON OFF Description The Dilution feature gives the user the ability to add hot water directly to the brew without passing through...

Страница 10: ...maximum length of time a brew remains fresh while being warmed Once the Warmer Timer has expired an alarm is generated An alarm consists of a blinking warmer LED and optionally the audible alarm buzze...

Страница 11: ...ust set the systems Real Time Clock Minutes placeholder ADJUST HOURS ADJUST HOURS DAY MM SS Description The Adjust Hours function allows the user to adjust set the systems Real Time Clock Hours placeh...

Страница 12: ...ntrol Card or Water Temperature Sensor OVER FLOW SYSTEM ERROR OVER FLOW Description This screen is displayed and the unit is disabled when the Over Flow Level Sensor is detecting the presence of water...

Страница 13: ...ASS Y 6 V210Q 1 V210Q 2 FUNNEL ASS Y BLACK 7 SF74Q 1 SC81Q 1 TANK WELDMENT ASS Y 8 R615A 1 SC86A 1 BASE WARMER COVER 9 G108A 1 G108A 2 WARMER ELEMENT 10 M090A 2 M090A 4 GROMMET F HEAT SHIELD 11 U485A...

Страница 14: ...83A 1 M483A 2 SILICONE HOSE 312 ID x 7 L 11 K671Q M197A 1 1 K671Q M197A 2 2 SPRAY HEAD FITTING ASS Y WITH RUBER WASHER 12 SD06Q E107A K668A 1 1 1 SD06Q E107A K668A 2 2 2 SPRAY HEAD BASE ASS Y SPRAY HE...

Страница 15: ...QTY P N BC2 IT BC302 IT QTY DESCRIPTION 1 L069A 1 L069A 1 POWER SWITCH 2 CD257 1 CD257 1 WATER INLET VALVE 3 B083A 1 B083A 1 TERMINAL BLOCK 4 CE202 1 CE202 1 POWER CORD 5 C396Q 1 C396Q 1 FUSE HOLDER A...

Страница 16: ...m of 3 min in the sanitizing solution Let all sanitized parts drain and dry naturally DO NOT WIPE THEM DRY Before using the sanitized unit or parts with food stuffs rinse all parts thoroughly with wat...

Страница 17: ...b Too much water in tank c Spray Head Fitting is clogged d Water Valve blocked by scales a Replace Water Dispense Valve b Dispense some water from tank c Clean Spray Head Fitting d Replace or clean V...

Страница 18: ...CD window Check the probe as follows Turn on the power from touchpad and water supply Check inside the tank to make sure the water is not touching the Probe Pull the wire and terminal out of the Probe...

Страница 19: ...GLE DISPENSE VALVE is factory adjusted to dispense 0 5 oz sec of water during the brew cycle spray duration b The DOUBLE DILUTION DISPENSE VALVE is factory adjusted on both sides to dispense 0 22 oz s...

Страница 20: ...6 8 12 14 J2 21 17 19 22 18 20 120VAC THERMISTOR L671A L2 N L1 TO SAFETY RELAY TO J3 PIN 3 TRIAC L623A 40A MT2 20 GA MT1 G 16 GA 20 GA TO FUSE 16 GA TO HEATER P5 KEYS WARM WARM PWR BERG CONNECT0RS P2...

Страница 21: ...MT2 G 7 6 T1 CH82A 120VAC 8VAC FUSE 6 AMP 17 18 18 17 SAFETY RELAY L553A K2 4 2 K1 3 1 100W 5 4 3 2 B190A SAFETY RELAY 10 9 1 3 2 4 5 7 6 8 13 14 11 12 15 16 1 10 1 3 5 7 2 4 6 8 13 11 9 15 14 12 16...

Отзывы: