TROUBLESHOOTING GUIDE 

WARNING:  To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal 
components of the unit..  Before any attempt to replace a component be sure to check all electrical connections for 

proper 

contact

 

PROBLEM

 

PROBABLE CAUSE

 

REMEDY

 

1. 

No power to the 

machine. 

a) Loose wire connection. 
b) Inoperative Power Safety Relay 
c) Blown fuse. 

a) Check wire connections to Relay.  See Power Safety Relay Test. 
b) Replace Power Safety Relay, if inoperative. 
c) Check fuse. 
 

2.  

Machine keeps 

repeating cycle.   

 

a) Touch Pad defective. 
b) Inoperative Power Safety Relay.

 

a) Replace Touch Pad. 
b) Replace Relay.

 

3. 

Water does not 

shut off.   Water 

keeps running into 

funnel.

 

a) Leaking Water Inlet Valve [Solenoid]. 
 
b) Inoperative Switches on Touch Pad. 
c) Clogged Dispense Valve 

 

a) Clean/check fittings of Valve.  Replace Valve if needed.   
    See ”Water Inlet Valve Test”  
b) Check Touch Pad connections.  Replace Touch Pad if needed. 
c) Clean Dispense Valve.   Replace Dispense Valve if inoperative.

 

3.  

 Water will not 

stop flowing into  

tank. 

 

a) Water Level Probe malfunction. 
b) Water Inlet Valve malfunction..

 

a)  Check Probe.  Replace if necessary.  See “Probe Test”  
b)  Check Solenoid.  Replace if necessary. See  “Water Inlet Valve 

Test” 

 

4.   

Water drips from 

brew funnel.

 

a) Leaking Dispense Valve. 
b) Too much water in tank. 
c) Spray Head Fitting is clogged. 
d) Water Valve blocked by scales.

 

a) Replace Water Dispense Valve. 
b) Dispense some water from tank. 
c) Clean Spray Head Fitting. 
d) Replace or clean Valve Seat.

 

5.   

No water  is going 

into tank at all.

 

a) Water Inlet Valve (Solenoid) malfunction. 
 
b) Water Level Probe malfunction. 

 

a) Check Water Inlet Valve.  Replace if necessary.    
    See “Water Inlet Valve Test”  
b) Check Probe.  Replace if necessary. See “Probe Test”.

 

6.  

 Water is not 

heating up in the 

water tank.

 

a) Temperature setting is incorrect.  
b) Loose connection to Heating Element or 

Heater Safety Relay. 

c) Heater is burned out or defective. 
d) Inoperative Heater Safety Relay.

 

a) Set Temperature at 200°F

 

– See Programming Instructions. 

b) Make sure all wires are tight. 
 
c) Replace the Heater. 
d) Replace Heater Safety Relay, if inoperative.  See Heater Safety 

Relay Test. 

 

7.  

Cold coffee.

 

a) Run out of hot water in tank. 
b) Temperature setting is incorrect. 
c) Loose electrical connection. 
d) Bad or burnt out Heating Element. 

 

a) Allow time for water in  tank to heat after filling. 
b) Set temperature at 200°F. (See Programming Instructions) 
c) Check all electrical connections for contact. 
d) Replace Heater.   

 

8.  

Coffee too strong.

 

a) Water flow too low. 
b) Too much coffee in the brew funnel. 

 

a) Adjust water flow rate on Dispense Valve. 
b) Put the proper amount of coffee in funnel.  See suggested amount.

 

9.  

Coffee too weak.

 

a) Not enough coffee in the brew funnel. 
b) Water flow too high.

 

a) Add coffee. 
b) Adjust water flow rate on Dispense Valve.

 

 
 
 
 

Содержание BC2-IT BC302-IT

Страница 1: ...0th Avenue Long Island City NY 11105 TEL 718 932 1414 FAX 718 932 7860 MODELS Single BC301 IT Twin BC2 IT BC302 IT MANUAL Specifications Installation Operating Instructions Programming Instructions Ca...

Страница 2: ...the tank and the Warmers The Brewer will automatically start filling the tank then it will start to heat up the Water in the tank until it reaches the proper preset temperature 200 F About 20 minutes...

Страница 3: ...totalizers for product marketing information and inventory control 7 Advanced system diagnostics that continuously monitor the status of valves sensors and heaters to ensure proper operation and aid i...

Страница 4: ...h as a double check valve to be installed between Brewer and water supply WATER CONNECTION The Brewer comes equipped with a inch compression water inlet fitting located in the back Use a inch copper t...

Страница 5: ...ol brewing Service Mode This mode becomes active when the hidden keys under the Cecilware Logo located on the upper left hand side of the keypad and the first letter of the Model Name located on the u...

Страница 6: ...displayed during the initial filling of the water tank first fill Once the water in the reservoir tank has reached the appropriate fill level this screen is retired Heating State HEATING DDD K TTTF H...

Страница 7: ...e Dilution Fill Constant Calibration State is entered from the Heating State or the Ready State by simultaneously pressing the Up Arrow Key and the Brew Key The system will immediately energize the Di...

Страница 8: ...to easily start a Brew Cycle while preventing unauthorized users from doing the same The presence of the KL symbol on the screen in Normal Mode indicates the status of KeyLock see Normal Mode Descript...

Страница 9: ...for any water remaining in the funnel to drain out DILUTION DILUTION 36 ON OFF Description The Dilution feature gives the user the ability to add hot water directly to the brew without passing through...

Страница 10: ...maximum length of time a brew remains fresh while being warmed Once the Warmer Timer has expired an alarm is generated An alarm consists of a blinking warmer LED and optionally the audible alarm buzze...

Страница 11: ...ust set the systems Real Time Clock Minutes placeholder ADJUST HOURS ADJUST HOURS DAY MM SS Description The Adjust Hours function allows the user to adjust set the systems Real Time Clock Hours placeh...

Страница 12: ...ntrol Card or Water Temperature Sensor OVER FLOW SYSTEM ERROR OVER FLOW Description This screen is displayed and the unit is disabled when the Over Flow Level Sensor is detecting the presence of water...

Страница 13: ...ASS Y 6 V210Q 1 V210Q 2 FUNNEL ASS Y BLACK 7 SF74Q 1 SC81Q 1 TANK WELDMENT ASS Y 8 R615A 1 SC86A 1 BASE WARMER COVER 9 G108A 1 G108A 2 WARMER ELEMENT 10 M090A 2 M090A 4 GROMMET F HEAT SHIELD 11 U485A...

Страница 14: ...83A 1 M483A 2 SILICONE HOSE 312 ID x 7 L 11 K671Q M197A 1 1 K671Q M197A 2 2 SPRAY HEAD FITTING ASS Y WITH RUBER WASHER 12 SD06Q E107A K668A 1 1 1 SD06Q E107A K668A 2 2 2 SPRAY HEAD BASE ASS Y SPRAY HE...

Страница 15: ...QTY P N BC2 IT BC302 IT QTY DESCRIPTION 1 L069A 1 L069A 1 POWER SWITCH 2 CD257 1 CD257 1 WATER INLET VALVE 3 B083A 1 B083A 1 TERMINAL BLOCK 4 CE202 1 CE202 1 POWER CORD 5 C396Q 1 C396Q 1 FUSE HOLDER A...

Страница 16: ...m of 3 min in the sanitizing solution Let all sanitized parts drain and dry naturally DO NOT WIPE THEM DRY Before using the sanitized unit or parts with food stuffs rinse all parts thoroughly with wat...

Страница 17: ...b Too much water in tank c Spray Head Fitting is clogged d Water Valve blocked by scales a Replace Water Dispense Valve b Dispense some water from tank c Clean Spray Head Fitting d Replace or clean V...

Страница 18: ...CD window Check the probe as follows Turn on the power from touchpad and water supply Check inside the tank to make sure the water is not touching the Probe Pull the wire and terminal out of the Probe...

Страница 19: ...GLE DISPENSE VALVE is factory adjusted to dispense 0 5 oz sec of water during the brew cycle spray duration b The DOUBLE DILUTION DISPENSE VALVE is factory adjusted on both sides to dispense 0 22 oz s...

Страница 20: ...6 8 12 14 J2 21 17 19 22 18 20 120VAC THERMISTOR L671A L2 N L1 TO SAFETY RELAY TO J3 PIN 3 TRIAC L623A 40A MT2 20 GA MT1 G 16 GA 20 GA TO FUSE 16 GA TO HEATER P5 KEYS WARM WARM PWR BERG CONNECT0RS P2...

Страница 21: ...MT2 G 7 6 T1 CH82A 120VAC 8VAC FUSE 6 AMP 17 18 18 17 SAFETY RELAY L553A K2 4 2 K1 3 1 100W 5 4 3 2 B190A SAFETY RELAY 10 9 1 3 2 4 5 7 6 8 13 14 11 12 15 16 1 10 1 3 5 7 2 4 6 8 13 11 9 15 14 12 16...

Отзывы: