![Cebora MONO STAR Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/cebora/mono-star/mono-star_instruction-manual_2577540012.webp)
12
the adjustment bar. Besides this function, the display
screen also shows
Pause Time
. If we select this, by
means of the adjustment bar, we can regulate the
pause time between one welding point or section and
another. The pause time varies between 0 (OFF) and 5
seconds.
To access the
Spot Time
and
Pause Time
functions,
press the knob
B
for less than 2 seconds. Adjustment
is always made by means of the knob
B
. To con
fi
rm,
simply press it for less than 2 seconds. Once the
choice has been con
fi
rmed, return is always made to
the display page (
PROCESS PARAMS
).
•
Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting
is zero. If the
fi
gure is negative, the impedance drops
and the arc becomes harder, while if it increases, the
arc is softer.
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The display
screen
A
shows the adjustment bar. The
fi
gure can be
changed and con
fi
rmed by pressing the knob
B
for less
than 2 seconds.
•
AUTO burnback
The adjustment can vary from -9.9 to +9.9. Its purpose
is to adjust the length of the wire coming out of the gas
nozzle after welding. A positive
fi
gure corresponds to
greater wire burning.
Default is Auto.
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The display
screen
A
shows the adjustment bar. The
fi
gure can be
changed and con
fi
rmed by pressing the knob
B
for less
than 2 seconds.
•
Soft Start AUTO
Adjustment can vary from 0 to 100%. This is the wire
speed expressed in percentage of the speed set
for welding, before the wire touches the piece to be
welded.
This adjustment is important to always obtain good
starts.
Default is Auto.
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The display
screen
A
shows the adjustment bar. The
fi
gure can be
changed and con
fi
rmed by pressing the knob
B
for less
than 2 seconds.
•
Options LOCK
To access this function, simply highlight it using the
knob
B
and press it for less than 2 seconds. The display
screen
A
will show a serial number
SN
and
8 zeros
.
The purpose of this function is to unlock the blocked
synergic curves.
To unlock the curves, instead of the zeros, an
alphanumeric code must be entered. This must be
requested from your dealer, after indicating the serial
number
SN
.
Once the code has been obtained, simply enter it in
place of the zeros, Each letter or
fi
gure entered must be
con
fi
rmed by brie
fl
y pressing the knob
B
. After entering
the code, by pressing the knob
B
for more than 2
seconds, all the curves are unlocked and the display
screen
A
shows
UNLOCK
alongside the Options
function.
• Factory OFF
The purpose is to return the welding machine to the
original default settings.
To access the function, simply highlight it using the
knob
B
. By pressing this for less than 2 seconds, the
display screen
A
shows the words
OFF
and
ALL.
By
highlighting the word
ALL
and brie
fl
y pressing the knob
B
reset is made and the display screen
A
shows
Factory
Done
!! This indicates the reset has been successful. To
return to the previous display page, simply press the
knob
B
for more than 2 seconds.