![Cebora CP 70C Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/cebora/cp-70c-series/cp-70c-series_instruction-manual_2577464020.webp)
20
ERROR DESCRIPTION
DISPLAY
POSSIBLE SOLUTION
Torch protection device not enabled
LED P
On (flashing:
1 blink + 2 sec. pause)
Fit the guard
Incorrect assembly of nozzle holder
LED P
On (flashing:
2 2 sec. pause)
Check that the nozzle holder is correctly
screwed into place
No torch recognition at start-up or re-
cognition modified in an invalid state
LED P
On (flashing:
3 2 sec. pause)
Contact the CEBORA Service Department
Electrode end of life
LED P
On (flashing:
4 2 sec. pause)
Replace electrode and nozzle
Reed contact closed during striking
LED P
On (flashing:
5 2 sec. pause)
Contact the CEBORA Service Department
Torch error
LED P
On (flashing:
7 2 sec. pause)
Contact the CEBORA Service Department
START button pressed at power up or
during reset after an error
LED P
On (flashing:
9 2 sec. pause)
Remove the START command
IGBT module over-temperature
LED O
On (steadily)
Do not turn off the power source, so as to
maintain the fan in operation and therefore
obtain effective cooling. Resetting of normal
operation occurs automatically once the
temperature returns within the permitted
limits. If the problem persists, contact the
CEBORA Service Department
.
Low air pressure at the inlet
LED Q
On (steadily)
Increase the gas supply pressure.