36/48
3301069/A
EN
G-H Negative output connector (-), Central adapter.
Connect the welding torch electrode terminal.
Use one as an alternative to the other according to the requirements of the torch used.
I
Plasma gas supply fitting. Connect the plasma gas supply pipe.
L
Shield gas supply fitting. Connect the shield gas supply pipe
�
L1
LED.
When this flashes, it indicates the HF generation phase for starting the pilot arc in manual operating mode
(section 5.2).
Flashing ends when the pilot arc is struck or after five seconds if the pilot arc is not struck.
L2
LED.
When lit, this indicates that the console is in standby. “Second function” parameter set-up and gas tests are
possible in this mode.
L3 LED.
When on, indicates console automatic or semi-automatic operating mode (section 5).
L4, L5, L6 LED.
When on, they indicate that the parameters shown by displays
D1, D2 and D3
can be adjusted by
means of knob
M1
�
L5 or L6
flash to indicate “gas test” mode.
M
Master switch.
Plasma console PW30 supply switch.
M1
Knob.
This incorporates a pushbutton:
- press
M1
for under 2 seconds to select parameter shown on displays
D1, D2 and D3
, to be adjusted by turning
M1
�
The selected display to be adjusted is indicated by LEDs
L4, L5 and L6.
The display selection disappears if
M1
is not operated within 5 seconds.
- press
M1
for longer than 2 seconds to access the console “second function” menu.
The functions, their status and values are indicated by displays
D1, D2 and D3
�
The “Second Functions” are described in section 7.
N
Supply cable
�
O
Auxiliary cooling circuit quick-fitting valve.
Connect the red pipe of the console – auxiliary cooling unit ex
-
tension (if available).
P
Auxiliary cooling circuit quick-fitting valve.
Connect the blue pipe of the console – auxiliary cooling unit
extension (if available).
Q
Main cooling circuit quick-fitting valve.
Connect the red pipe of the console – power source – cooling unit
extension (33).
R
Main cooling circuit quick-fitting valve.
Connect the blue pipe of the console – power source – cooling unit
extension (33).
S
Male connector
. Connect the female connector of the console – power source – cooling unit extension (33).
SW1 Selector for inserting line termination resistor on CAN bus-1
�
If the console is at one end of the CAN bus line (see example in fig. 2 without wire feeder (8)),
SW1
must be in
ON position (resistor inserted).
If the console is at an intermediate position on the CAN bus line (see example in fig. 2) SW1 must be in OFF
position (resistor not inserted).
Refer also to manual for TIG power source Item No 3301062.
T1 Key.
Select operating modes (section 5):
- press
T1
for longer than 2 seconds to control Manual operation and starting
of the pilot
arc;
- press
T1
for under 2 seconds to control Automatic operation.
T2 plasma gas test key.
- press
T2
so that plasma gas emerges from the torch.
LED L5
flashes to indicate
testing.
- press
T2
a second time to stop plasma gas emerging from the torch.
LED L5
goes off.
T3 shield gas test key
�
- press
T3
so that shield gas emerges from the torch. LED L6 flashes to indicate testing.
- press
T3
a second time to stop shield gas emerging from the torch. LED
L6
goes off.
Keys T2 and T3 can be used to bleed the system pipes. Gases can be bled from the TIG power source in the TEST
section.
Содержание 465.01
Страница 11: ...11 25 3301069 A IT 5 5 5 48 0 1 3 4 2 fig 4a fig 4b ...
Страница 25: ...25 25 3301069 A IT 9 DIAGRAMMA TEMPORIZZAZIONI DEL PROCESSO PLASMA WELDING ...
Страница 35: ...35 48 3301069 A EN 5 5 5 48 0 1 3 4 2 fig 4a fig 4b ...
Страница 48: ...48 48 3301069 A EN 9 PLASMA WELDING PROCESS TIMING DIAGRAM ...
Страница 58: ...58 76 3301069 A ES 5 5 5 48 0 1 3 4 2 fig 4a fig 4b ...
Страница 72: ...72 76 3301069 A ES 9 DIAGRAMA DE TEMPORIZACIONES DEL PROCESO PLASMA WELDING ...
Страница 73: ...73 76 3301069 A 3301069 ...
Страница 74: ...74 76 3301069 A ES ...
Страница 75: ...75 76 3301069 A ES ...