7.8

 

Soft Start (Acc). 

This regulation is important in order to obtain good starts. 
Soft  start  is  the  wire  speed,  expressed  in  percentage  of  wire  speed  set  for  welding,  before  that  the  wire 
touches the workpiece. 
Press for a time longer than 3 seconds the key 

E

 to enter the “Second Functions” menù. 

Use knob 

N

 to select 

Acc

 on display 

O

; with knob 

Q

 select the Soft Start speed level, visible on display 

P

 

(indication expressed in percentage). 
Regulation range: Auto or 1 ÷ 100%, default = 

Au

, automatic. 

 
NOTE: In order to verify the value corresponding to the default value, rotate of a single step clockwise 

the knob 

Q

, when display 

P

 indicates 

Au

, and subtrac “1” to the value that appears on display 

P

Obviously, after such operation, rotating counter-clockwise of a single step knob 

Q

, the operation 

will be set to the value visible on display 

P

 but not automatic. In order to restore the  automatic 

operation (default) press for a time longer than 3 seconds the key 

AZ

 
Press briefly the key 

E

 to exit the “Second Functions” menù, saving all current settings automatically. 

 
7.9

 

Burn-Back Time Correction (bb). 

Regulation  for  the  wire  length  exiting  the  torch  nozzle  after  welding,  expressed  as  a  time  interval 
(milliseconds). 
Press for a time longer than 3 seconds the key 

E

 to enter the “Second Functions” menù. 

Use  knob 

N

  to  select 

bb

  on  display 

O

;  display 

P

  shows  the  function  value  (indication  expressed  in 

milliseconds). 
Correction regulation range: -125 ÷ +125 ms. 
The 

Burn-Back Time

 effective value after the correction is always comprised between 4 ms. and 250 ms. 

When  the  correction  set  up  is  equal  to  0  the 

Burn-Back  Time

  parameter  is  set  to  its  default  value, 

indicated with 

Au

 (automatic). 

The 

Burn-Back  Time  Correction

  adjustment  is  enabled  or  disabled  by  means  the 

Burn-Back  Time 

Correction Disable

 function, available on RAI211 and RDI210 Robot Interfaces. 

The corresponding bit is controlable with dip switch S1-4 on RAI211 Robot Interface or with the signal 
“I100”  of  the  Data-In  Process  Image  on  RDI210  Robot  Interface  (see  Robot  Interface  Instruction 
Manual): 
-

 

with 

“Burn-Back  Time  Correction  Disable”

  not  active  (S1-4  =  OFF,  or  I100  =  low)  the 

“Burn-

Back  Time  Correction”

  adjustment  is  enabled  in 

Standard  program,

 

Pulsed  arc  program

  and 

Manual 

modes, and follows the value set at Robot Interface analog input 4. The adjustment is carried 

out via Robot Terminal; 

-

 

with  “

Burn-Back  Time  Correction  Disable

”  active  (S1-4  =  ON,  or  I100  =  high)  the  “

Burn-back 

Time Correction

” is not active. 

Independently  from  the 

Burn-Back  Time  Correction  Disable

  function  state,  in 

Parameter  Selection 

Internal mode

, is always possible to adjust the 

Burn-Back Time Correction

 from Control Panel. 

When  the  Control  Panel  is  operating,  knob 

Q

  executes  the 

“Burn-Back  Time  Correction”

  function 

value  regulation  and  the  key 

AZ

,  pressed  for  a  time  longer  than  3  seconds,  resets  the  function  to  the 

default value (

Au

 on display 

P

). 

 
NOTE: In order to verify the value corresponding to the default value, rotate of a single step clockwise 

the knob 

Q

, when display 

P

 indicates 

Au

, and subtrac “1” to the value that appears on display 

P

Obviously, after such operation, rotating counter-clockwise of a single step knob 

Q

, the operation 

will be set to the value visible on display 

P

, but not automatic. In order to restore the automatic 

operation (default) press for a time longer than 3 seconds the key 

AZ

 
Press briefly the key 

E

 to exit the “Second Functions” menù, saving all current settings automatically. 

Содержание 208-10

Страница 1: ...S MANUAL FOR MIG POWER SOURCES IN ROBOT APPLICATIONS pag 23 E MANUAL DE ISTRUCCIONES PARA PANEL DE CONTROL Art 208 10 PARA GENERADORES MIG EN APPLICACIONES ROBOT pag 44 Esempi di profili di corrente C...

Страница 2: ...mori eccedenti gli 80dB Il procedimento di taglio plasma saldatura pu produrre livelli di rumore superiori a tale limite pertanto gli utilizzatori dovranno mettere in atto le precauzioni previste dall...

Страница 3: ...NI DI SERVIZIO 15 6 1 RICHIAMO DI UN PROGRAMMA MEMORIZZATO DA TERMINALE ROBOT 15 6 2 RICHIAMO DI UN JOB MEMORIZZATO DA TERMINALE ROBOT 15 6 3 RICHIAMO DI UN JOB MEMORIZZATO DA PANNELLO DI CONTROLLO 15...

Страница 4: ...ni dell Interfaccia Robot Eseguire i restanti collegamenti delle altre apparecchiature del Sistema di Saldatura consultando i relativi Manuali di Istruzioni al par Installazione Alimentare il Sistema...

Страница 5: ...lo WF4 R1 art 1657 WF4 R2 art 1658 10 Guaina del filo di saldatura art 1935 00 l 1 6 m art 1935 01 per Marathon Pack 21 Generatore MIG 3840 T art 287 80 MIG 5040 T art 289 80 22 Gruppo di Raffreddamen...

Страница 6: ...ni del Sistema di Saldatura mentre le selezioni operate da Terminale Robot sono bloccate NOTA In Parameter Selection Internal mode possibile richiamare uno dei programmi memorizzati e variarne i param...

Страница 7: ...n punto di lavoro precedentemente memorizzato realizzato partendo da un programma di Saldatura MIG MIG Short o MIG Pulsed al quale sono stati modificati da parte dell utente alcuni parametri Per la se...

Страница 8: ...Pannello di Controllo mantiene una operativit parziale condizionata dalla Modalit Operativa selezionata Per abilitare la funzione Robot premere per un tempo maggiore di 3 secondi il tasto AV Il led AT...

Страница 9: ...ode e Manual mode indica che display O visualizza la velocit del filo in saldatura impostata nel programma richiamato In Parameter Selection Internal mode indica che display O visualizza la velocit de...

Страница 10: ...globulare Quando acceso segnala che la coppia di valori di Velocit del filo e Tensione di saldatura scelti per la saldatura pu dare archi instabili e con spruzzi 4 8 Led F Hold Si accende alla fine d...

Страница 11: ...ompleta no PrG nel caso di messaggio di errore del Generatore visualizza il numero dell errore Su display O appare la sigla Err nel men Funzioni di Servizio visualizza le scelte possibili in risposta...

Страница 12: ...a Robot RAI217 5 1 2 numero di programma o numero di Job Selezione di un numero di programma o numero di Job da richiamare 8 segnali disponibili 8 bits 0 7 per Interfaccia Robot RAI211 3 segnali dispo...

Страница 13: ...zzati su display P quando il led J si spegne Normalmente il led J acceso per indicare che il display P visualizza una tensione di saldatura durante la variazione della Correzione della Lunghezza d Arc...

Страница 14: ...le non attiva S1 4 OFF o I100 basso la regolazione Burn Back Time Correction abilitata nei modi Standard program Pulsed arc program e Manual e segue il valore impostato sull ingresso analogico 4 dell...

Страница 15: ...modalit Job mode curve sinergiche modificate dall utente ed un numero di Job diverso da 0 zero Display O visualizza PrG e display P visualizza il numero di Job scelto Dopo 3 secondi su Pannello di Co...

Страница 16: ...e si intende cancellare l indicazione sul display P diventa fissa per indicare il numero di un Job esistente Con manopola N scegliere la sigla dEL su display O Premere il tasto AZ per un tempo maggior...

Страница 17: ...nzionare e si arresta 3 minuti dopo la scomparsa del segnale di start Se la pressione del liquido refrigerante insufficiente il Generatore non eroga corrente e su display O compare il messaggio H2O la...

Страница 18: ...a Con la funzione CrA attiva diventano disponibili altri suoi parametri selezionabili con manopola N Slo su display O tempo di passaggio tra corrente di saldatura e corrente di cratere con manopola Q...

Страница 19: ...parametro Burn Back Time al suo valore di default indicato con Au automatico La regolazione Burn Back Time Correction attivabile o disattivabile mediante la funzione Burn Back Time Correction Disable...

Страница 20: ...alore di default 0 0 su display P Premere brevemente il tasto E per uscire dal men Seconde Funzioni memorizzando automaticamente tutte le impostazioni attuali 7 11 Doppia Pulsazione dP optional su art...

Страница 21: ...iva blocca il Generatore se dopo lo start Arc On il filo esce per una lunghezza maggiore di quella assegnata alla funzione max 50 cm senza passaggio di corrente Premere per un tempo maggiore di 3 seco...

Страница 22: ...e 06 09 10 10 per art 289 Operativa solo in Parameter Selection Internal mode Imposta il Firmware del Generatore alle condizioni originali di fabbrica Premere per un tempo maggiore di 3 secondi il ta...

Страница 23: ...is machine does not directly produce noise exceeding 80dB The plasma cutting welding procedure may produce noise levels beyond said limit users must therefore implement all precautions required by law...

Страница 24: ...S FROM ROBOT TERMINAL 34 6 SERVICE FUNCTIONS 36 6 1 CALLING UP A SAVED PROGRAM FROM THE ROBOT TERMINAL 36 6 2 CALLING UP A SAVED JOB FROM THE ROBOT TERMINAL 36 6 3 CALLING UP A SAVED JOB FROM THE CONT...

Страница 25: ...n Manual Complete the remaining connections of the other Welding System equipments consulting the corresponding Instruction Manuals at par Installation Power up the Welding System using the BU switch...

Страница 26: ...1 7 MIG Torch 8 Wire Feeder unit WF4 R1 art 1657 WF4 R2 art 1658 10 Welding wire sheath art 1935 00 l 1 6 m art 1935 01 per Marathon Pack 21 Power Source MIG 3840 T art 287 80 MIG 5040 T art 289 80 22...

Страница 27: ...l control of the Welding System functions while selections from the Robot Terminal are blocked NOTE In Parameter Selection Internal mode it is possible to call up one of the saved programs and change...

Страница 28: ...Job mode it is possible to call up a previously saved working point developed starting from a MIG MIG Short or MIG Pulsed welding program in which the user has modified some parameters For the select...

Страница 29: ...itches to the Robot Terminal and the Control Panel maintains partial operation conditioned by the Operating Mode selected To enable the Robot function press for a time longer than 3 seconds the key AV...

Страница 30: ...Program mode Pulsed Arc Program mode Job mode and Manual mode indicates that display O shows the welding wire speed set in the selected program In Parameter Selection Internal mode indicates that dis...

Страница 31: ...f values for Wire speed and Welding voltage chosen for welding may give unstable arcs and splatters 4 8 Led F Hold Activated at the end of each welding session When lit it signals that the values show...

Страница 32: ...or message of the Power Source it displays the error number Display O shows the abbreviation Err in the Service Functions men displays the possible choices in response to the function shown on display...

Страница 33: ...h Robot Intrface RAI217 5 1 2 program number or Job number Selecting a program number or Job number to call up 8 signals available 8 bits 0 7 with Robot Intrface RAI211 3 signals available 3 bits 0 2...

Страница 34: ...n on display P when the led J is off Normally the led J is lit in order to indicate that display P shows a welding voltage during the Arc Length Correction variation the correction function is marked...

Страница 35: ...F or I100 low the Burn Back Time Correction adjustment is enabled in Standard program Pulsed arc program and Manual modes and follows the value set at Robot Interface analog input 4 The adjustment is...

Страница 36: ...rminal select Job mode synergic curves changed by the user and a Job number other than 0 zero Display O shows PrG and display P shows the selected Job number After 3 seconds the Control Panel displays...

Страница 37: ...te the message on display P becomes steady to indicate the number of an existing Job Use knob N to choose the abbreviation dEL on display O Hold down the AZ key for a time longer than 3 seconds an aco...

Страница 38: ...s after the start signal goes away If the coolant pressure is too low the Power Source delivers no current and the message H2O will appear flashing on the display O 7 2 Way of operation trG With the R...

Страница 39: ...n active other parameters become available selectable with knob N Slo on display O time for switching between welding current and crater current use knob Q to assign a value to the field Slo visible o...

Страница 40: ...ck Time parameter is set to its default value indicated with Au automatic The Burn Back Time Correction adjustment is enabled or disabled by means the Burn Back Time Correction Disable function availa...

Страница 41: ...d for a time longer than 3 seconds resets the function to the default value 0 0 on display P Press briefly the key E to exit the Second Functions men saving all current settings automatically 7 11 Dou...

Страница 42: ...cks the Power Source if after the start Arc On the wire comes out longer than the length assigned to the function max 50 cm without any output current Press for a time longer than 3 seconds the key E...

Страница 43: ...arting with the firmware in release 4 for art 287 and 06 09 10 10 for art 289 Operative in Parameter Selection Internal mode Sets the Power Source Firmware to the original factory conditions Press for...

Страница 44: ...rocedimiento de corte plasma soldadura puede producir niveles de ruido superiores a tal l mite por tanto los utilizadores deber n actuar las precauciones previstas por la ley PACE MAKER Los campos mag...

Страница 45: ...6 FUNCIONES DE SERVICIO 57 6 1 DEMANDA DE UN PROGRAMA MEMORIZADO DESDE TERMINAL ROBOT 57 6 2 DEMANDA DE UN JOB MEMORIZADO DESDE TERMINAL ROBOT 57 6 3 DEMANDA DE UN JOB MEMORIZADO DESDE PANEL DE CONTRO...

Страница 46: ...ual de Instrucciones de la Interfaz Robot Efectuar las restantes conexiones de los dem s dispositivos del Sistema de Soldadura consultando los correspondientes Manuales de Instrucciones en el p rrafo...

Страница 47: ...ilo WF4 R1 art 1657 WF4 R2 art 1658 10 Funda del hilo de soldadura art 1935 00 l 1 6 m art 1935 01 per Marathon Pack 21 Generador MIG 3840 T art 287 80 MIG 5040 T art 289 80 22 Grupo de Enfriamiento G...

Страница 48: ...as que las selecciones actuadas por el Terminal Robot est n bloqueadas NOTA En Parameter Selection Internal mode se puede buscar uno de los programas memorizados y variar los par metros para efectuar...

Страница 49: ...precedentemente memorizado realizado partiendo de un programa de Soldadura MIG MIG Short o MIG Pulsed en el cual han sido modificados por parte del usuario algunos par metros Para la selecci n tenemos...

Страница 50: ...Panel de Control mantiene una operatividad parcial condicionada por la Modalidad Operativa seleccionada Para habilitar la funci n Robot presionar para un tiempo mayor de 3 segundos la tecla AV El led...

Страница 51: ...display O visualiza la velocidad del hilo en soldadura programada en el programa requerido En Parameter Selection Internal mode indica que display O visualiza la velocidad del hilo en soldadura progra...

Страница 52: ...Cuando encendido se ala que el par de valores de Velocidad del hilo y Tensi n de soldadura elegidos para la soldadura puede dar arcos inestables y con salpicaduras 4 8 Led F Hold Se enciende al final...

Страница 53: ...rG sigla completa no PrG en el caso de mensaje de error del Generador visualiza el n mero del error En el display O aparecer la sigla Err en el men Funciones de Servicio visualiza las posibles eleccio...

Страница 54: ...ts 0 1 para Interfaz Robot RAI217 5 1 2 n mero de programa o n mero de Job Selecci n de un n mero de programa o n mero de Job por requerir 8 se ales disponibles 8 bits 0 7 para Interfaz Robot RAI211 3...

Страница 55: ...el display P cuando el led J se apaga Normalmente el led J es encendido para indicar que el display P visualiza una tensi n de soldadura durante la variaci n de la Correcci n de la Longitud del Arco...

Страница 56: ...o activa S1 4 OFF o I100 bajo la regulaci n Burn Back Time Correction es habilita en Standard program Pulsed arc program y Manual mode y sigue el valor fijado a la entrada anal gica 4 de la Interfaz R...

Страница 57: ...ot la modalidad Job mode curvas sin rgicas modificadas por el usuario y un n mero de Job diverso de 0 cero Display O visualiza PrG y display P visualiza el n mero de Job elegido Pasados 3 segundos en...

Страница 58: ...n mero de Job que se piensa anular la indicaci n en el display P se vuelve fija para indicar el n mero de un Job existente Con manecilla N elegir la sigla dEL en el display O Presionar la tecla AZ pa...

Страница 59: ...el grupo se detendr a A cada mando de start Arc On el grupo inicia a funcionar y se detiene 3 minutos despu s de la desaparici n de la se al de start Si la presi n del liquido refrigerante fuese insuf...

Страница 60: ...cionar el estado de la funci n visible en el display P OFF no activa default On activa Con la funci n CrA activa se vuelven disponibles otros par metros selecci nables con manecilla N Slo en el displa...

Страница 61: ...ms Cuando la correcci n fijada es igual a 0 el par metro Burn Back Time est a su valor de default indicado con Au autom tico La regulaci n Burn Back Time Correction se puede activar mediante la funci...

Страница 62: ...0 en el display P Presionar la tecla E para salir del men Segundas Funciones memorizando autom ticamente todas las programaciones actuales 7 11 Doble Pulsaci n dP optional en el art 287 Operativa en...

Страница 63: ...iva bloquea el Generador si despu s del start Arc On el hilo sale de una longitud mayor de la asignada a la funci n m x 50 cm sin paso de corriente Presionar para un tiempo mayor de 3 segundos la tecl...

Страница 64: ...Operativa solo in Parameter Selection Internal mode Programa el Firmware del Generador a las condiciones originales de f brica Presionar para un tiempo mayor de 3 segundos la tecla E para entrar en el...

Страница 65: ...iles examples For greater clarity some examples of current profiles and welding program tables are listed below E Ejemplos de perfiles de corriente Para mayor claridad se citan a continuaci n algunos...

Страница 66: ...than welding current Main Current Profile 4 Automatic Hot Start HSA profile with Crater Arc CrA function The Starting Current SC is higher than Main Current and the filling Crater Current CrC is lower...

Страница 67: ...CEBORA S p A 67 3 300 189 B 04 03 2016...

Страница 68: ...te 8 Pannello comando Command panel 9 Connessione Connection 10 Circuito Pannello di Controllo Control Panel circuit La richiesta di pezzi di ricambio deve indicare sempre numero di articolo matricola...

Отзывы: