7.4
Automatic Hot Start (HSA).
Press for a time longer than 3 seconds the key
E
to enter the “Second Functions” menù.
Use knob
N
to select
HSA
on display
O
; with knob
Q
select the function status, visible on display
P
:
OFF
= not active (default);
On
= active.
With the
HSA
function active, other parameters become available, selectable with knob
N
:
SC
on display
O
(“hot-start” current level); use knob
Q
to assign a value to the field
SC
, visible on
display
P
. Regulation range: 10 ÷ 200 s, default = 135;
tSC
on display
O
(“hot-start” current lasting time); use knob
Q
to assign a value to the field
tSC
,
visible on display
P
. Regulation range: 0.1 ÷ 10.0 s, default = 0.5;
SLo
on display
O
(time for switching between “hot-start” current and welding current); use knob
Q
to
assign a value to the field
tSC
, visible on display
P
. Regulation range: 0.1 ÷ 10.0 s, default = 0.5.
Press briefly the key
E
to exit the “Second Functions” menù, saving all current settings automatically.
7.5
Crater Arc (CrA).
Available starting with the firmware in release 6 for art. 287 and 13 for art. 289.
Press for a time longer than 3 seconds the key
E
to enter the “Second Functions” menù.
Use knob
N
to select
CrA
on display
O
; with knob
Q
select the function status, visible on display
P
:
OFF
= not active (default);
On
= active.
With the
CrA
function active, other parameters become available, selectable with knob
N
:
Slo
on display
O
(time for switching between welding current and crater current); use knob
Q
to
assign a value to the field
Slo
, visible on display
P
. Regulation range: 0.1 ÷ 10.0 s, default = 0.5;
CrC
on display
O
(percentage of wire speed during welding, corresponding to welding current); use
knob
Q
to assign a value to field
CrC
, visible on display
P
. Regulation range: 100 ÷ 200 % of wire
speed set for welding, default = 60%;
tCr
on display
O
(duration of the crater current); use knob
Q
to assign a value to the field
tCr
, visible
on display
P
. Regulation range: 0.1 ÷ 10.0 s, default = 0.5.
Press briefly the key
E
to exit the “Second Functions” menù, saving all current settings automatically.
7.6
Pre Flow (PrF).
Press for a time longer than 3 seconds the key
E
to enter the “Second Functions” menù.
Use knob
N
to select
PrF
on display
O
; with knob
Q
select the duration time of the Gas Pre Flow, visible
on display
P
(indication expressed in seconds).
Regulation range: 0 ÷ 10 s, default = 0.1.
Press briefly the key
E
to exit the “Second Functions” menù, saving all current settings automatically.
7.7
Post Flow (PoF).
Press for a time longer than 3 seconds the key
E
to enter the “Second Functions” menù.
Use knob
N
to select
PoF
on display
O
; with knob
Q
select the duration time of the Gas Post Flow,
visible on display
P
(indication expressed in seconds).
Regulation range: 0 ÷ 25 s, default = 3.
Press briefly the key
E
to exit the “Second Functions” menù, saving all current settings automatically.