![Cebora 208-10 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/cebora/208-10/208-10_instruction-manual_2577434030.webp)
CEBORA S.p.A.
30
3.300.189-B
04/03/2016
GB
4.2
AI key - Choice of the welding process.
Operative in
Parameter Selection Internal mode
.
Each time the key is pressed selects a different welding process, indicated by the lighting of the
corresponding led.
Led R1 -
Pulsed Synergic MIG/MAG Process.
Led R2 -
Non-pulsed Synergic MIG/MAG Process.
Led R3 -
Conventional MIG/MAG process.
4.3
E key.
The pressure for a time smaller than 3 seconds recalls the parameter indicated by the lighting of leds
AU
,
B
,
C
and
D
, whose value is visualized on display
O
, or it puts into effect the “Second Functions” menu
exit.
The pressure for a time greater than 3 seconds, perform the “Second Functions” menu input.
4.3.1
Led AU - Program number.
In
Standard Program mode
,
Pulsed Arc Program mode
,
Parameter Selection Internal mode
and
Manual mode
, indicates that display
O
shows the “program number”.
4.3.2
Led B - Thickness.
In
Standard Program mode,
Pulsed Arc Program mode, Job mode
and
Manual mode
, indicates that
display
O
shows the recommended thickness based on the current and wire speed set by the selected
program.
In
Parameter Selection Internal mode
, indicates that display
O
shows the recommended thickness
based on the current and wire speed set. The value may be changed using the knob
N
. This change affects
the value of the set voltage, which may be seen on display
P
, with led
J
lit.
4.3.3
Led C - Wire speed.
In
Standard Program mode
,
Pulsed Arc Program mode
,
Job mode
and
Manual mode
, indicates that
display
O
shows the welding wire speed set in the selected program.
In
Parameter Selection Internal mode
, indicates that display
O
shows the welding wire speed set in the
selected program. The value may be changed using the knob
N
. This change affects the value of the set
voltage, which may be seen on display
P
, with led
J
lit.
4.3.4
Led D - Current.
In
Standard Program mode
,
Pulsed Arc Program mode
and
Job mode
, indicates that display
O
shows
the welding current preset in the selected program or, if in
combination with led
F
lit, the measured actual
welding voltage.
In
Manual mode
, display
O
reads 0 (zero). Only after a welding, in combination with led
F
lit, indicates
the measured actual welding current.
In
Parameter Selection Internal mode
, indicates that display
O
shows the preset welding current of the
selected program. The value may be changed using the knob
N
. This change affects the value of the set
voltage, which may be seen on display
P
with led
J
lit.
4.4
Knob N.
In every Operating Mode, other than
Job mode,
adjusts the values indicated by the leds
AU
,
B
,
C
and
D
.
The value is shown on display
O
.
In “Service Functions” it selects the abbreviations
Sto, dEL
and
rcL,
related to the functions “store”
Sto
,
“delete”
dEL
and “recall”
rcL
. The abbreviations are visible on display
O
.
Based on the function called up, the “Second Functions” menu displays the abbreviations
H2O, trG, SP
(tSP, tIn), HSA (SC, tSC, Slo), CrA (Slo, CrC, tCr), PrF, PoF, Acc, bb, L, dP (FdP, ddP, tdP, Adp),
Ito, HFU, FPE, Fac.
The abbreviations are visible on display
O
.
Содержание 208-10