GALEO
Illuminated RF Keypad
INSTALLATION MANUEL
UTILE
Operator for sectional and overhead doors
INSTALLATION MANUAL
EN
4
erone.com
4] Dimensions
6] Preliminary recommendations
•
Installation and testing must be carried out only by qualified personnel to guarantee the
correct and safe functionality of the automatic gate.
•
The manufacturer declines all responsibility for damages deriving from any incorrect
installation due to incapacity and / or negligence.
•
Before proceeding with the installation of the automatiion, check that the door is fully
functional and balanced.
5] Technical specifications
Parameter
70 Kg
100 Kg
Max height overhead door
3000 mm
Max height sectional door
2700 mm
Door max width
3000 mm
4500 mm
Operator power supply
230 Vac
Motor power supply
24 Vdc
Motor power
50 W
100 W
Emergency unblocking system
Mechanical-internal / External
Operating temperature
-20°C / +55°C
Weight
4 Kg
Enclosure protection
IP30
Opening time 90°
22 sec.
Torque
600 N
1000 N
Motor current consumption
0,7A
1,2 A