GALEO
Illuminated RF Keypad
INSTALLATION MANUEL
UTILE
Operator for sectional and overhead doors
INSTALLATION MANUAL
EN
10
erone.com
8] Troubleshooting
Drawback
Probable cause
Solution
The gate doesn’t open or the motor
doesn’t move after a command from
remote control, key switch
Line power absent
Check the main switch
Emergency STOP active
Check for any the selectors or STOP
commands. If not used check the
presence of the bridge on the STOP
input on the control panel
Blown Fuse
Replace it with another identical or of
the same value
Motor power cord
disconnected or defective
Connect the motor power cord to the
corresponding terminal or replace it
Obstacle on the photocells
beam
Check the connection and / or remove
the obstacle
The command is executed by the
key switch and not by the remote
control
The remote control has
not been memorized or its
battery is low
Check the memorization of the remote
control on the receiver of the control
panelor replace the transmitter battery
The gate starts but stops
immediately
the torque of the motor is
insufficient
Change the torque using the trimmer
“Torque” on the control panel
At a command, the
engine starts but the door does not
move
There is an obstacle in front
of the door, the hinges
are blocked or
detached or the brackets of
motor anchorage have
detached
Remove the obstacle,
restore the hinges,
replace them or register them.
Fix the bracket(s) of the
motor
note
: if the problem persists, contact your dealer or the nearest assistance center