C. Changing the master code

 

The master code is used only 

 

to enter in programming mode.

 

1. Enter the master code twice    

 

    

(

1 2 3 4 5 

default value master code).

  

 

    2 beeps are emitted to confirm entry 

 

    in programming mode.

 
 

2. Press A5 to modify the master code.    

  

- One beep is emitted.  

 

  - Enter the new 4, 5 or 6-digits master code.  

 

  - One beep is emitted to confirm 

 

 

    that the master code is programmed.

 

3. Press B to exit from 

 

    the programming mode.  

 

 

    

2 beeps are emitted to confirm that the 

 

 

    keypad is in stand-by operating mode.

D.

 

Adding, changing or 

  deleting a user code

 

User location 00 to 59 is relay 1

 

User location 60 to 99 is relay 2

 

1. Enter the master code twice    

 

    

(

1 2 3 4 5 

default value master code).

  

 

    2 beeps are emitted to confirm entry 

 

    in programming mode.

 

2. To add a user code, enter the user  

 

 

    location (from 00 to 99). 

    

If the user location is used 4 beeps  

 

 

    are emitted, enter the 4, 5 or 6-digits  

 

 

    user code.

 

3. To Change a User code enter 

 

    the user location. 

  

-

 

4 beeps are emitted to indicate that  

 

 

    the user location is already programmed.    

 

  - Enter a new 4, 5 or 6-digits code. 

 

  - A beep is emitted to confirm the new  

 

 

    user code.

 

4. To delete a User code enter 

 

    the user location. 

  

-

 

4 beeps are emitted. 

 

  - Press 

0 as many times as digits 

 

    in the user code.

 

  ( ex. 0 0 0 0 0

 in 5-digits length code )

 

  - A beep is emitted to confirm the user 

 

 

    code has been deleted.

 

 

Note:

If the Pin code is already programmed or is 

identical to the master code, then 4 beeps are 

emitted. Press B to exit from the programming 

mode. 2 beeps are emitted to confirm that the 

keypad is in stand-by operating mode.

E.  Time outputs

 

This section allows to program 

 

the illumination time and the Relay 

 

activation time.

 

1. Enter the master code twice    

 

    

(

1 2 3 4 5 

default value master code).

  

 

    2 beeps are emitted to confirm entry 

 

    in programming mode.

 

2. Press A0 to program the key-in  

 

 

    keypad time and the keys lit time.  

 

 

  -1 beep is emitted.  

  

-

 

Enter the time in seconds with 2 digits – 

10  

 

    for 10 seconds up to 99 for 99 seconds. 

 

 

    The backlighting dims after 10 seconds after

 

 

    the last keypress or switches off after 

 

 

    entering a valid code.    

 

 

 

  - Press 

00

 for permanent illumination keys.    

 

  - One beep is emitted to validate the time.

 

3. Press A1 to program relay 1 

 

    output time (door release time).

 

    (Press A2 for relay 2).

  

-

 

1 beep is emitted.  

 

  - For a latched output enter the time  

 

    in seconds using 2 digits – 

01 for 1 second  

 

    up to 99 for 99 seconds. 

 

  - Press 

00

 for a toggled output. 

 

  - One beep is emitted to validate the time.

 

4. Press B to exit from 

 

    the programming mode.  

 

 

    

2 beeps are emitted to confirm that the 

 

 

    keypad is in stand-by operating mode.

 

4 beeps indicate a data computing error.

Содержание DGA

Страница 1: ...1 FI NO DK SE EN DGA Keypad DGA ...

Страница 2: ...TION IP64 Environmental tests Salt spray 25 C à 70 C HIGH RESISTANCE TO VANDALISM Recommended power supplies ADC335 230V input BS60 230V input Separate power supply for the control elements Wiring reminder Make sure to insulate any unused wires Mounting recommendations Mount the keypad on a flat surface to avoid any vandalism and to insure the best mounting Security advice For security advice reas...

Страница 3: ... and a meter tape and follow the mounting instructions of the DGA keypad Take the marks with the back plate of the DGA Drill the 2 mounting holes Ø 5 MM bit and 35 MM depth minimum and the wiring access hole Insert the 2 plastic anchors Then mount the back plate of the DGA keypad and screw on the wall with the M4x30 mounting screws Insert the cable of the keypad in the wiring access area Place the...

Страница 4: ...voltage 12V or 24V AC or DC Red Input voltage 12V or 24V AC or DC Brown Relay 1 N C contact Pink Relais 1 common Orange Relay 1 N O contact Yellow Common Dark Green Relay 1 request to exit input Light Green H Timer input Blue User code modification Dark Blue Relay 2 N C contact Purple Relais 2 common Gray Relay 2 N O contact White Reset Varistor INPUT VOLTAGE 12Vac to 24Vac 12Vdc to 48Vdc INPUT VO...

Страница 5: ...des 1 Enter the master code twice 1 2 3 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press A6 to reset the Master Code and the User codes One beep is emitted Press on A and B to confirm reset of all memory of the keypad Wait for two beeps The master code is restored to its default value 1 2 3 4 5 and all the user codes are deleted from the keypad Once th...

Страница 6: ... Press 0 as many times as digits in the user code ex 0 0 0 0 0 in 5 digits length code A beep is emitted to confirm the user code has been deleted Note If the Pin code is already programmed or is identical to the master code then 4 beeps are emitted Press B to exit from the programming mode 2 beeps are emitted to confirm that the keypad is in stand by operating mode E Time outputs This section all...

Страница 7: ...s feature makes it easier and faster to change its code 1 Enter the master code twice 1 2 3 4 5 default value master code 2 beeps are emitted to confirm entry in programming mode 2 Press A7 to program a sub master code for the user individual Pin code modification Press A8 for relay 2 One beep is emitted Enter the new 2 digits sub master code One beep is emitted to confirm programming of the sub m...

Страница 8: ... default Time relay 2 01 99 sec 00 toggled 01 default Code length 4 5 or 6 digits 5 default Master code Change master code 12345 default 2 x beeps 1 x beep OK 4 beeps ERROR A0 1 x beep OK 4 beeps ERROR A1 1 x beep OK 4 beeps ERROR A2 1 x beep OK 4 beeps ERROR A4 1 x beep OK 4 beeps ERROR A5 1 x beep OK 1 x beep OK 1 x beep OK 1 x beep OK 1 x beep OK ...

Страница 9: ...t Sub master code 1 2 digits 13 default Sub master code 2 User codes 4 5 or 6 digit code 4 beeps user location used 1 beep user location free 1 x beep OK Press B to exit from programming AA A6 1 x beep OK 4 beeps ERROR A7 1 x beep OK 4 beeps ERROR A8 1 x beep OK 00 99 1 x beep OK 4 beeps ERROR 2 x beeps OK 1 x beep OK 1 x beep OK 1 x beep OK ...

Страница 10: ... 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 User location Code Name 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 User location Code Name 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Relay 1 From user location 00 to 59 Relay 2 From user location 60 to 99 ...

Страница 11: ...ils of this warranty and to register the product to commence the Limited Lifetime Warranty complete the enclosed registration card and return it either by e mail or post to the relevant CDVI address or completion of the on line registration at www cdvigroup com Repair or replacement of the defective product is the exclusive remedy CDVI shall not be liable for any incidental or consequential damage...

Страница 12: ...CIFIKATION IP64 Miljötest Salt spray 25 C till 70 C HIGH RESISTANCE TO VANDALISM Rekommenderade nätaggregat ADC335 230Vac BS60 230Vac Separat nätaggregat för tillkopplade enheter Kablage Se till att isolera alla trådar som ej används Monteringsrekommendation Montera kodlåset på en plan yta för att förhindra vandalism och för att få bästa möjliga montage Säkerhets tips för koder Av säkerhetsskäl bö...

Страница 13: ...ngarna för DGA kodlås Sätt kodlåsets bakstycke mot väggen och markera hålens placering med en penna Borra sedan två monterings hål minst Ø 5 mm bits och min djup 35 mm och hål för kablen Sätt plastpluggarna i de borrade hå len Placera kodlåsets bakstycke mot väggen och skruva fast med de bifo gade skruvarna Trä kabeln genom kabelhålet i bakstycket Kroka fast kodlåset på bakstycket genom att föra d...

Страница 14: ...eskrivning Svart Inspänning 12 24 VAC eller 12 48 VDC Röd Inspänning 12 24 VAC eller 12 48 VDC Brun N C kontakt relä 1 Rosa Gemensam relä 1 Orange N O kontakt relä 1 Gul Gemensam externingång Mörkgrön Ingång för extern tryckknapp relä 1 Ljusgrön Timeringång H Ljusblå Ändring av användarkod Mörkblå N C kontakt relä 2 Lila Gemensam relä 2 Grå N O kontakt relä 2 Vit Återställning VARISTOR INSPÄNNING ...

Страница 15: ... Skriv in den nya 4 5 eller 6 siffriga masterkoden En pipsignal bekräftar den nya masterkoden 4 Tryck B för att lämna programmeringsläget Två pipsignaler bekräftar att knappsa sen är i standbyläge och redo att användas 4 pip indikerar ett databehandlingsfel Standard inställningar Utan koder Tidsinställd belysning 10 sekunder Reläslutningstid 1 sekund Kodlängd 5 siffror Masterkod 1 2 3 4 5 Tidsinst...

Страница 16: ... att platsen är upptagen Tryck lika många 0 som kodlängden t ex 0 0 0 0 0 för 5 siffriga koder En pipsignal bekräftar användarkoden har raderats Notera Om användarkoden redan är programmerad eller densamma som masterkoden så hörs fyra pipsignaler Tryck B för att gå ur programmer ingen Två pipsignaler bekräftar att knappsat sen är i standbyläge och redo att användas E Programmera tider Här programm...

Страница 17: ...sterkod med jämna mellanrum 1 Knappa in masterkoden två gånger Masterkodens standardvärde 1 2 3 4 5 Två pipsignaler bekräftar att man är i programmeringsläget 2 Tryck A7 för att programmera under masterkod Tryck A8 för relä 2 En pipsignal hörs Skriv in en ny 2 siffrig undermasterkod En pipsignal bekräftar den nya under masterkoden 3 Tryck B för att lämna programmeringsläget Två pipsignaler bekräft...

Страница 18: ...g relä 1 01 99 sek 00 växlande 01 standard Tidsinställning relä 2 01 99 sek 00 växlande 01 standard Kodlängd 4 5 eller 6 siffror 5 standard Masterkod 4 5 eller 6 siffror 12345 standard 2 x pip 1 x pip OK 4 pip FEL A0 1 x pip OK 4 pip FEL A1 1 x pip OK 4 pip FEL A2 1 x pip OK 4 pip FEL A4 1 x pip OK 4 pip FEL A5 1 x pip 1 x pip 1 x pip 1 x pip 1 x pip ...

Страница 19: ... användarkod 2 siffror AB standard Undermaster kod 1 2 siffror 13 standard Undermaster kod 2 Programmera användarkoder 4 5 eller 6 siffror 4 pip upptagen användarplats 1 pip ledig plats Tryck B för att avsluta programmeringen 1 x pip OK 4 pip FEL AA 2 x pip OK A6 1 x pip OK 4 pip FEL A7 1 x pip OK 4 pip FEL A8 1 x pip OK 00 99 1 x pip 1 x pip 1 x pip 1 x pip ...

Страница 20: ...19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Reläutgång 1 Plats 00 till plats 59 Reläutgång 2 Plats 60 till plats 99 PM Plats Kod Namn 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 Plats Kod Namn 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 ...

Страница 21: ...ch att registrera produkten för att påbörja begränsad livstids garanti fyll i det bifogade registreringsbeviset och återsänd detta antingen via post eller e mail till närmaste CDVI kontor eller registrera online på www cdvigroup com Reparation eller utbyte av den defekta produkten är de två alternativ som finns CDVI ansvarar inte för oförutsedda skador eller följdskador Inte under några som helst ...

Страница 22: ...BELGIUM NETHERLANDS LUXEMBOURG 32 0 56 73 93 00 www cdvibenelux com CDVI TAIWAN 886 0 42471 2188 www cdvichina cn CDVI SUISSE 41 0 21 882 18 41 www cdvi ch CDVI CHINA 86 0 10 84606132 82 www cdvichina cn CDVI IBÉRICA SPAIN PORTUGAL 34 0 935 390 966 www cdviberica com CDVI ITALIA 39 0 321 90 573 www cdvi it CDVI MAROC 212 0 5 22 48 09 40 www cdvi ma CDVI NORDICS SWEDEN DENMARK NORWAY FINLAND 46 0 3...

Отзывы: