EN
EN
DGA
Keypad DGA
5
cdvigroup.com
Default values
- Without codes.
- Illumination time: 10 seconds
.
- Relay release time: 1 second
.
- Code length: 5-digits
.
- Master Code:
1 2 3 4 5.
- Programming security time :
120 secondes.
- Code length for sub master code:
Version 1 relay
(Group 1) =
AB
,
Version 2 relays
(Group 2) =
13
.
- One beep on switching on.
Audible signal:
- The buzzer indicates different
audible signals.
-
1 short beep
: Keypad powered.
-
1 long beep
: Data computing
in programming or access
granted.
-
2 short beeps
: Enter or Exit
from programming.
-
4 short beeps
:
data computing error.
Code length
- The master code and the user
codes can be of 4 to 6-digits
in length.
- All the keypad keys can be used
to program a code.
- The master code CAN NOT
be used as a user code.
- To delete a specific User pin Code
replace it by
0 0 0 0
if code
length is 4-digits format or
replace it by
0 0 0 0 0
if the
code is in 5-digits format.
or
replace it by
0 0 0 0 0 0
if the
code is in 6-digits format.
Reset:
- Turn off the power to the
keypad.
- Short the white and the yellow
wires.
- Turn on the power to the
keypad.
- Wait for a few seconds, one
beep is emitted.
- Unshort the wires.
- The keypad is reset to default
values.
A. Reset master code
and user codes
1. Enter the master code twice
(
1 2 3 4 5
default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press A6 to reset the Master Code
and the User codes.
- One beep is emitted.
- Press on
A
and
B
to confirm reset
of all memory of the keypad.
- Wait for two beeps.
- The master code is restored to its default
value
1 2 3 4 5
and all the user codes
are deleted from the keypad.
- Once the reset is completed then the keypad
returns to a stand-by operating mode.
OR
1. Cut the power. Short the wires yellow
and white.
2. Put the power back.
-
Wait approximately 3 seconds.
- Two beeps are emitted to confirm reset
of the keypad.
- Unshort the wires.
- The master code is restored to its default
value
1 2 3 4 5
and all the User codes
are deleted from the keypad.
B. Setting code length
1. Enter the master code twice.
(
1 2 3 4 5
default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press A4 to program the code length.
- One beep is emitted.
- Press
4, 5
or
6
for the digit code.
- One beep is emitted to confirm
programming of the code length.
3. Press A5 to modify the master code.
- One beep is emitted.
- Enter the new 4, 5 or 6-digits master code.
- One beep is emitted to confirm
programming of the new master code.
4. Press B to exit from
programming mode.
2 beeps are emitted to confirm that the
keypad is in stand-by operating mode.
4 beeps indicate a data computing error.
Содержание DGA
Страница 1: ...1 FI NO DK SE EN DGA Keypad DGA ...