27
OK
Interpose the
supplied gasket.
Important !
Use two wrenches to tighten
the connection.
LOCK
LOCK
Arrow
Important !
Use two wrenches to tighten the connection.
Note: take care not to overtighten the coni-
cal adaptor, as doing so may crack the test
point adaptor.
Rc 1/2 conical
(ISO 7-1) female
Rc 1/2 conical
(ISO 7-1) female
R 1/2 conical
(ISO 7-1) male
G 1/2 cylindrical
(ISO 228-1) female
G 1/2 cylindrical
(ISO 228-1) male
Test point
Test point adaptor
Conical adaptor
Gasket
Nipple
Appliance
gas inlet pipe
Installing the Test Point Adaptor
Using a suitable leak detection flu-
id solution (e.g. Rocol) check each
gas connection one at a time by
brushing the solution over the con-
nection.
The presence of bubbles will indica-
te a leak.
If there is a leak, tighten the fitting
and then recheck for leaks.
IMPORTANT! Do not use a naked fla-
me to test for leaks.
Fig. 34
Fig. 35
Fig. 36
Fig. 37