12
CD3000S
2PH from 10A to 90A
User’s manual
3.2 Order Code
CURRENT (A)
4
5
6
description
Code
OLD code
Note
10A
0
1
0
10A
1
15A
0
1
5
15A
25A
0
2
5
25A
35A
0
3
5
35A
45A
0
4
5
45A
75A
0
7
5
75A
90A
0
9
0
90A
1
OPERATING VOLTAGE (V)
-
description
Code
OLD code
Note
From 24V to Max Load Voltage
not in the code
_ _ _V
MAX LOAD VOLTAGE (V)
7
description
Code
OLD code
Note
480V
4
600V
6
AUXILIARY VOLTAGE (V)
8
description
Code
OLD code
Note
NO Auxiliary Voltage supply
0
NO /
12÷24V with analog input / HB Alarm
4
12:24 /
2,3
INPUT
9
description
Code
OLD code
Note
SSR from 4 to 30Vdc
S
SSR /
Analog Input 0÷10V
A
0÷10V /
3,5
Analog Input 4÷20mA
V
4÷20mA /
3,5
FIRING
10
description
Code
OLD code
Note
Zero Crossing with SSR Input
Z
ZC /
4 cycles on + 4 off with Analog Input
4
BF004 /
8 cycles on + 8 off with Analog Input
8
BF008 /
16 cycles on + 16 off with Analog Input
6
BF016 /
CONTROL MODE
11
description
Code
OLD code
Note
Open loop
0
not in the code
FUSES & OPTION
12
description
Code
OLD code
Note
No Fuse / No Option
0
NF / -
No Fuse / HB Option for SSR input
1
NF / HB
5
No Fuse / HB Option for analog input
1
5
External Fuse & Fuse Holder / No Option
F
EF / -
External Fuse & Fuse Holder / HB Option
for SSR input
2
EF / HB
5
External Fuse & Fuse Holder / HB Option
for analog input
2
EF / HB
5
FAN VOLTAGE
13
description
Code
OLD code
Note
No Fan for unit <75A
0
- /
Fan 110V Option - for 75A and 90A units
1
110VFAN/
Fan 220V Standard - for 75A and 90A units
2
not in the code
APPROVALS
14
description
Code
OLD code
Note
CE EMC for European Market
0
- /
CE EMC + cUL us listed
L
UL /
MANUAL
15
description
Code
OLD code
Note
None
0
NM
Italian
1
IM
English
2
EM
German
3
GM
French
4
FM
IP PROTECTION
16
description
Code
OLD code
Note
Standard IP20 (all unit excluded 45A, 75A,
90A)
0
- /
External IP20 protection for size S7/S8
(45A, 75A, 90A)
P
EP /
(1)
For 10A 600V and for 90A cUL us not available
(2)
Necessary with 0÷10V - 4÷20mA or HB alarm
(3)
Option available from 45 to 90A
(4)
IP20 is standard on all units with exception of S7 and S8 size (45-75-90A).
To complain IP20 use “P” option at digit 16
(5)
HB option not available with UL approval
New Code (example):
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CD3000S 2PH
D
S
2
0
7
5
-
4
4
V
8
0
1
2
0
2
P
Old Code (example):
Model
Current
(A)
Operating
Voltage
(V)
Max Load
Voltage
(V)
Aux
Voltage
(V)
Input
Firing
Fuses
HB
Option
EP
Option Approvals Manual
CD3000S 2PH / 75A / 400V / 480V / 12:24V / 4-20mA / BF008 / EF / HB / EP / - / EM
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CD3000S 2PH
D
S
2
_
_
_
-
_
_
_
_
_
_
_
_
_
_
Содержание CD3000S2PH