8
Control with External Signals
Specifications for External Control
Communications Specifications
Communications protocol
Baud rate
Data bit length
Parity bit
Stop bits
EIA-485 compliant
19,200 bps
8 bits
None
1 bit
Connector Layout
External Control Connector Plug
3 2 1
No.
Signal
Cable (ECXCB2-E3-3)
Enlarged Cable Diagram
Wire color
Line color
1
I/O+
2
I/O−
FG
Black
Black
Drain wire
None
White
3 (shield)
Line color
Wire color
Drain wire
ABCDEFGHIJKLMNOPQRSTUVWXYZ 0123456789
Sample of Alphanumeric Characters:
Command Formats
Send Data
(*1)
Light Intensity Setting
Lighting Mode Setting
ON/OFF Setting
Setting Status Check
Error status check
All Channel Initialization
Function
@
Header
<CR><LF>
Delimiter
F
S
L
M
C
R
Instruction
Sent command
00 to 03
(Refer to *7)
ID specification
00 to FF
(Refer to *8)
Checksum
000
00
(Refer to *9)
- - -
- - -
- - -
Default
000 to 255 (Refer to *4)
00 to 10 (Refer to *5)
0: Not lit, 1: Lit (Refer to *6)
- - -
- - -
- - -
Data (*2)
Channel specification
00 (fixed)
00 to 03
(Refer to *3)
FF: All channels
(ON/OFF setting only).
Receive Data
(*10)
<CR><LF>
Delimiter
00 to 03
(Refer to *7)
ID specification
00 to FF
(Refer to *8)
Checksum
Received command
OK
O
- - -
- - -
F999.S99.L9 (Refer to *11)
00: Normal, 11: Error
NG
N
01: Command error
03: Set value out
of range error
02: Checksum error
Light Intensity Setting
Lighting Mode Setting
ON/OFF Setting
Setting Status Check
Error status check
All Channel Initialization
Function
@
Header
Channel specification
00 (fixed)
00 to 03
(Refer to *3)
FF: All channels
(ON/OFF setting only).
<< Annotation>>
*6)
ON/OFF setting from EIA-485 communications without regards to trigger logic switch, turned OFF at ‘0’ and ON at ‘1’. ON/OFF setting will not be held after turning the power off.
When operating EIA-485 communications and trigger signal input at same time in ON/OFF mode.
When Trigger logic switch is at HIGH: if ether controls setting to OFF setting, Light unit will be turned OFF
When Trigger logic switch is at LOW: if ether controls setting to ON setting, Light unit will be turned ON
*1)
Send a data within 4 seconds from 'Header' to 'Delimiter', otherwise time-out error occurs and command data will be rejected.
*2)
Specify all numbers in decimal format.
*3)
Channel Specification
L2
L3
L1
01
02
00
L4
03
Channel
Set value
*4)
Light Intensity Settings
*5)
Lighting Mode Settings
40μs
80μs 120μs 200μs 600μs 1ms
4ms
10ms 20ms 40ms
01
02
03
04
05
06
07
08
09
10
00
(Set values that are higher
than 10 are not valid.)
Strobe Mode
Digital window
Set value
Continuous Mode
or ON/OFF Mode
Status
Select the lighting mode form Continuous Mode, ON/OFF Mode, or Strobe Mode. The lighting time can be set in Strobe Mode.
(The Strobe Mode can be set for 24V DC Light Units only.) For details on the external trigger input, refer to 9. Inputting the External Trigger.
The light intensity is controlled to any of 256 levels. 000 to 255 (000: Minimum, 255: Maximum)
000
0.0
(Not lit)
0.4
(Dimly lit)
Light Intensity
(%)
HLV LIGHT
24V LIGHT
001
0.4
002
0.8
254
99.6
255
100.0
0.8
1.2
99.6
100.0
* The light intensities are theoretical values.
Digital window
Set value
Set the value to 00 to enter
Normal Mode and keep the Light
Unit lit continuously.
Set the value to 00 to enter ON/OFF Mode and turn the
Light Unit ON and OFF. The Light Units are turned ON or
OFF according to the external trigger signal input.
Select the lighting time from 01 to 10 (40 µs to 40 ms) to use a strobe light.
The Light Units are turned ON for the set time after the external trigger
signal is input. The Strobe Mode can be set for 24V DC Light Units only.
Continuous Mode
ON/OFF Mode
(If the external trigger is not used, the Light Units are ON continuously.)
Strobe Mode
(If an external trigger is not used, the Light Units are OFF.)
Four channels from L1 to L4 are allocated to the 24V LIGHT and HLV LIGHT output connectors. When L1 is selected, settings for the L1 Light Unit for the
24V LIGHT connectors and the HLV LIGHT connectors can be changed. The 4 channels can be controlled separately.
(Set values that are higher than 03 are not valid.)
66