99
11
Optional Accessories (Sold Separately)
Model: EXCB2-M10-3
External Trigger Input Cable
Connector: XG4M-1030-T (manufactured by OMRON)
9
1
2
10
3000
150
+
0
5 dia.
Cut off on one end
10-pole MIL connector
Cut off on one end
e-CON 3-pole connector
1
2
3
150
+
3000
0
3.9 dia.
Model: EXCB2-E3-3
External Control Cable
Connector: 37103-3122-000FL (manufactured by Sumitomo 3M Limited)
External Control Junction Cable
External Control Junction Cable Model: EXCB2-E3-E3-0.2
e-CON 3-pole connector
3.9 dia.
10
+
200
0
1
2
3
Connector: 37103-3122-000FL (manufactured by Sumitomo 3M Limited)
Junction Connector Model: ECNR-E3CN4
30
13.8
13
Connector: 5-1473574-3 (manufactured by Tyco Electronics Japan G.K.)
10
Errors
When detecting the error during external control, command will be received as
acknowledgement for checking status (over current confirmation) command “C”.
(This applies only to overcurrent errors and fan stop errors.)
Error Output
For details, refer to 8. Control with External Signals.
12
Troubleshooting
If you have any problems during product usage, please look up the cause in this chart. If the situation does not improve, or an unexpected situation
occurs, please contact CCS Inc.
Symptom
Items to check for fixing the problem
If no Light Unit has ever been
connected to the same channel in the 24V
LIGHT connectors, EId will be displayed.
If a Light Unit is connected to the
same channel in the 24V LIGHT connectors,
“ .” is displayed. (“ ” is the set value.)
HLV ID Error
A Spotlight outside the ID range was
connected to an HLV LIGHT connector.
If the channel that is connected to a Spotlight that is
outside the ID range is selected, an error will be displayed.
Light Units that are connected to 24V
LIGHT connectors can be set normally.
Overcurrent Error
The current consumption of the Light
Unit exceeded 107% of the rating.
Fan Stop Error
The fan has stopped.
Clearing the error
Output is
stopped.
Output is
stopped.
Normal
Recovery method
OR
(Example display)
Period
Check the rating of the
LED Light Unit. Connect
an LED Light Unit that is
within the rating.
Press and hold the
setting switch or
cycle the power.
Press and hold the
setting switch or
cycle the power.
Operation recovers
automatically.
Doing so may cause
product failure.
Consult a CCS
representative.
Check the Spotlight.
Connect a Spotlight
that is supported by
the Control Unit.
If an internal error occurs in the Control Unit, it is displayed on the digital window.
Refer to the following table and clear the error before using the Control Unit again.
Digital Window
Error
Status
Symptom
Items to check for fixing the problem
Reference
page
Lights not
illuminating.
Light intensity
control is not
possible.
Are all power sources turned ON?
Is the LED light cable inserted firmly into the output connector?
Is the AC cord inserted firmly into the AC inlet and a wall
socket?
Does the digital window show an error?
Check the error display.
Is an appropriate Light Unit connected to the output
connector? Check the Light Unit.
Is the output connector the correct one for the connected
Light Unit? Connect 24V DC Light Units to the 24V LIGHT
connectors and Spotlights to HLV LIGHT connectors.
Is the lighting mode set correctly?
Set the lighting mode to F00 for Continuous Mode or
ON/OFF Mode.
Does the logic of the trigger signal match the trigger
signal setting switch?
Is the external trigger input OFF (in ON/OFF Mode or Strobe
Mode)? Check the setting method and sequence diagram.
Is the manual/external switch set correctly?
Set it to MANU to operate manually and to EXT for
external control.
Is an appropriate Light Unit connected to the output
connector? Check the Light Unit.
Is the output connector the correct one for the connected
Light Unit? Connect 24V DC Light Units to the 24V LIGHT
connectors and Spotlights to HLV LIGHT connectors.
Have the wrong channels been selected?
Check the channels whose lights are to be controlled.
Is the setting switch locked?
Press and hold the setting switch for more than two
seconds to release the lock.
3
3
3
4
5, 6
8
8
9
5, 6
4
4
4
5, 6
5
External control is
not possible.
Is the external control cable inserted firmly into the
external control connector and an external device?
Was the command sent correctly?
Set the data correctly.
Are the ID switches set correctly?
Do the ID designation and the ID switches agree?
If the Control Unit has more than one Light Unit
connected on the same signal line, is the external control
junction cable connected securely to the external control
connector on the Control Unit?
Is the external trigger input cable inserted firmly into the
external trigger input connector and an external device?
Are the external trigger input cable and external devices
wired correctly?
Check the connector configuration and correct the wiring.
Is the lighting mode set correctly?
Set the value to F00 for ON/OFF Mode.
Set the value to F01 to F10 for Strobe Mode.
Is the signal setting correct?
Check the setting method and sequence diagram.
Please use designated power sources with stable voltage.
Sharing power sources with inverters, motors, etc., may
cause malfunction.
Do not bundle product cables with high-voltage lines or power
lines. Doing so may cause the product to malfunction. Keep
the product cables as far away from such lines as possible.
There is a possibility of product failure. Please stop usage
immediately and turn OFF the power switch.
Please do not attempt to use or repair the product, since
it is dangerous, but contact CCS Inc.
3
6, 7
6, 7
7
Unable to turn the
Light Unit ON and
OFF or use strobe
control.
3
8
5, 6
8
Malfunctioning.
Fuming, extreme
temperature, smell,
noise, or other
abnormality.
-
-
-
Symptom
Items to check for fixing the problem
Reference
page