* Rated capacity per connector: 3.9 W max.
  (700mA max.) 

Total for all connectors×8

* Total rated capacity: 46 W max.

PWM control or lighting time control

46W max.

Depends on the power consumption of the Light Units.

Depends on which Light Units are connected/disconnected.

Detected when connected for the first time.

0.5 s

Item

Applicable illuminators

Lighting method

Lighting 

mode

Control 

mode

Rated capacity

Lighting delay time

Channel selection

Light Unit connection detection

Power startup time

Continuous mode

ON/OFF mode

Strobe mode

Manual control

External control

Variable current control

---

Per connector: 3.9 W max. (700mA max.) 

Depends on the light intensity of the Light Unit.

Only connected Light Units can be selected.

Detected at any time.

3 s

10

5, 6

5, 6

5, 6

5

6, 7

10

8

5

5

10

10

Spotlights

24V DC Light Units

Spotlights: HLV2 series, HLV series*

 *not including HLV-27 series/HLV-14-R/

HLV-14-GR/HLV-14-BL/HLV-14-SW

Reference

page

Light Unit Functions

This Control Unit can be connected to Light Units and Spotlights with 24V DC inputs. Connect 24V DC Light Units to the 24V LIGHT connectors and 
Spotlights to HLV LIGHT connectors. The functions vary with the Light Units that are connected. Check the following table before using the Light Units.

Output Connectors (24V LIGHT) 

Output Connectors (HLV LIGHT) 

Light Units with 24V DC input voltage

Содержание PD3-5024-4-SI

Страница 1: ...esult in electric shock Make sure that the product is free of moisture or any liquid Doing so may result in fire or electric shock Before connecting or disconnecting cables make sure that the power so...

Страница 2: ...lets or fan exhaust outlets Insufficient ventilation may cause heat to accumulate inside the product and result in a fire Mounting the Unit to DIN Rail Mounting to DIN Rail Hook the tab on the upper p...

Страница 3: ...urned OFF with manual or external control To use ON OFF Mode or Strobe Mode connect the external trigger input cable to the external trigger input connector Insert the connector to the Light Unit all...

Страница 4: ...nal control Variable current control Per connector 3 9 W max 700mA max Depends on the light intensity of the Light Unit Only connected Light Units can be selected Detected at any time 3 s 10 5 6 5 6 5...

Страница 5: ...lash the strobe turn the setting switch and select a setting from F01 to F10 strobe time of 40 s to 40 ms The Light Units are turned ON for the period of time set on the setting switch after the exter...

Страница 6: ...switch is at LOW if ether controls setting to ON setting Light unit will be turned ON 1 Send a data within 4 seconds from Header to Delimiter otherwise time out error occurs and command data will be r...

Страница 7: ...The Control Units are identified with the ID switch settings Up to four Units can be connected to one signal line The EIA 485 communications circuit will be terminated inside the Control Unit if the...

Страница 8: ...us Photocoupler OFF Photocoupler ON Light Unit status Trigger Logic Switch Set to LOW The Light Units turn ON when the photocoupler is ON and OFF when the photocoupler is OFF Trigger Logic Switch Set...

Страница 9: ...output connector Is the AC cord inserted firmly into the AC inlet and a wall socket Does the digital window show an error Check the error display Is an appropriate Light Unit connected to the output...

Страница 10: ...Y EXCLUDED EXCEPT AS EXPRESSLY SET FORTH HEREIN CCS MAKES NO WARRANTIES WITH RESPECT TO THE PRODUCTS WARRANTY PERIOD TWO YEARS STARTING FROM CCS Inc SHIPPING DATE CCS Inc WILL REPAIR OR REPLACE THE PR...

Отзывы: