- 11 -
9. Specifications
Product name
Control Unit for LED Light Units
Model PD2-3012-2(A) PD2-3024-2(A)
Lighting method
Constant lighting
Drive method
Constant-voltage system
Light control method
PWM control
No. of channels
2 channels
Applicable
illumination (rating)
12V
28W 24V
28W
PWM frequency
62.5KHz
Light
control
Manual
Use of the intensity control knobs on the front panel (Coarse, Fine)(Each 16 steps)
External
Input in negative logic (B0 to B7), Manual/External control (NT/EXT),
The write bit (WR), Lighting ON/OFF (ON1, ON2), Channel selection (CH)
Error detection
display
The Error indicator (red) on the front panel is lit when overcurrent is detected.
Error detection
output
External control connector 14 pin (OCP): Open collector ON when overcurrent is detected.
Over current
protection
*1)
Operates at 107% min.
Automatically reset, or manually reset by turning power OFF then ON again.
Input voltage
(rating)
100 to 240V AC
Input voltage
(range)
85 to 264C
Power consumption
(typ.)
78VA
Frequency 50/60Hz
Inrush current (typ.)
15A (at 100V AC) Note: From a cold start
Ground leakage
current
3.5mA max.
(264C, 60Hz, ith no load)
Output voltage
(rating)
12V DC
24V DC
Output current
(rating)
2.3A (total for 2 channels)
1.1A (total for 2 channels)
External
control
(input)
Insulation
Non-insulated with power supply for illuminator.
Circuit
Internally pulling up to +5V power supply by resistance (4.7k
Ω
) HS-CMOS input
Dielectric strength
(input-output, input-FG)
1500V AC for one minute 10mA cutoff current
500V DC, 20M
Ω
min.
Operating temperature
and humidity
Temperature: 0 to 40°C, Humidity: 20 to 85%RH (No condensation)
Storage temperature
and humidity
Temperature: -20 to 60°C, Humidity: 20 to 85%RH (No condensation)
Vibration resistance
Acceleration: 19.6 m/s
2
, frequency: 10 to 55 Hz, cycles: 3 minutes,
for 1 hour each in X, Y, and Z directions
Cooling method
Natural air cooling
Altitude 2000m
max.
Protective ground
Class I
Pollution level
Pollution level II
Over voltage category
Category II
CE marking
Safety standard conform to EN 61010-1
EMC standard conform to EN 61326-1 Class A
Input
connector
AC iput
3-pin, EN 60320-1-certified, C14-type connector x 1
L type terminal, N type terminal, PE type terminal
Содержание PD2 Series
Страница 14: ...14 MEMO...
Страница 15: ...15 MEMO...