Inputting an External Trigger
9
Input Signal and Photocoupler
The input signal from the external trigger input connector can be used to control the
photocoupler inside the Unit to turn the LED Light Units ON and OFF or to control
strobe timing. The operation depends on the setting of the trigger logic switch.
Lighting Delay Time
The lighting delay time for lights connected to 24V LIGHT connectors depends on the power
consumption of the Light Unit. The lighting delay time for Spotlights connected to HLV
LIGHT depends on the intensity of the Spotlights. Refer to the following graphs and tables.
* The data in the graphs show reference values when a Light Unit or Spotlight with a 5-m cable is used. (The values are for reference only.)
Lighting Delay Time (typ.)
Light Intensity
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
610μs 260μs 180μs 130μs 110μs 82μs 73μs 65μs 60μs 55μs
Light Intensity vs. Lighting Delay Time Characteristic
(HLV LIGHT)
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
0
20
40
60
80
100
Light Intensity (%)
Power Consumption vs. Lighting Delay Time Characteristic (24V LIGHT)
0
2
4
6
8
9
7
5
3
1
10
10
20
30
40
50
Power Consumption (W)
Trigger Input Sequence Diagram
(Only 24V DC Light Units can be set.)
Lit
Lit
Not lit
Not lit
Not lit
Not lit
Trigger Logic
Switch
ON/OFF
Mode
Input signal
Light Units ON
Light Units ON for the set time.
Light Units OFF
No change
Light Units OFF
No change
Light Units ON
Light Units ON for the set time.
Photocoupler
Strobe Mode
9 7 5 3 1
10 8 6 4 2
Connector Layout
No.
Black 1
Red 1
Black 1
Red 1
---
Red 1
Light Unit ON/OFF control input (L1)
Light Unit ON/OFF control input (L2)
Light Unit ON/OFF control input (L3)
Light Unit ON/OFF control input (L4)
Not used.
1
2
3
4
5 to 9
10
Orange
Orange
Gray
Gray
---
Pink
External Trigger Input
Connector Plug
Enlarged Cable Diagram
Pink
Red 1
Example: Pin No. 10, pink, red 1
Wire color
Marks
Signal
Cable (EXCB2-M10-3)
ON/OFF Mode
Trigger Logic Switch Set to HIGH
The Light Units turn ON when the photocoupler is OFF, and OFF
when the photocoupler is ON.
Strobe Mode
Photocoupler OFF
Photocoupler ON
Light Unit status
Photocoupler OFF
Photocoupler ON
Light Unit status
Photocoupler OFF
Photocoupler ON
Light Unit status
Photocoupler OFF
Photocoupler ON
Light Unit status
Trigger Logic Switch Set to LOW
The Light Units turn ON when the photocoupler is ON, and OFF
when the photocoupler is OFF.
Trigger Logic Switch Set to HIGH
From the point where the photocoupler goes OFF, the Light Units are
turned ON for the set time (40 µs to 40 ms).
Trigger Logic Switch Set to LOW
From the point where the photocoupler goes ON, the Light Units are
turned ON for the set time (40 µs to 40 ms).
40 µs to 40 ms
40 µs to 40 ms
10 µs min.
External Trigger Signal Connection Example
1
10
24V DC
COMMON
12kΩ
Light Unit ON/OFF
control input L1
PD3 Control Unit
External Circuits
Transistor (NPN)
open collector
* When operating trigger signal input and Ethernet communications at same time in ON/OFF mode.
When Trigger logic switch is at HIGH: if either controls setting to OFF setting, Light unit will be turned OFF
When Trigger logic switch is at LOW: if either controls setting to ON setting, Light unit will be turned ON
10 µs min.
Lit
Lit
Not lit
Not lit
Not lit
Not lit
Lit
Lit
Not lit
Not lit
Not lit
Not lit
Lit
Lit
Not lit
Not lit
Not lit
Not lit
Lighting Delay Time (typ.)
Power Consumpiton
Refer to “Lighting delay time”.
Refer to “Lighting delay time”.
Refer to “Lighting delay time”.
Refer to “Lighting delay time”.
Lighting Delay Time
(
μs
)
Lighting Delay Time
(
μs
)
If another trigger is input before the Light Unit turns OFF in Strobe Mode, the starting point of the reentered trigger is taken as the start time and the strobe light continues for the set time from that point.
A pulse width of ON signal shall be 10μs or more. The Light Units will be truned on for at least 40μs, even when the input ON signal is less than 40μs.
10 µs min.
40 µs min.
10 µs min.
40 µs min.
Connection Specifications (for Each Terminal)
Rated
input voltage
Maximum
input voltage
24V DC
26.4V DC
14.4V DC min./
1 mA min.
5V DC max./
0.4 mA max.
Refer to the
Trigger Input
Sequence Diagram
, below.
Photocoupler
ON voltage/ON current
Photocoupler
OFF voltage/OFF current
Response time