background image

99

10

Errors

             If no Light Unit has ever been 
connected to the same channel in the 24V 
LIGHT connectors, EId will be displayed.

             If a Light Unit is connected to the 
same channel in the 24V LIGHT connectors, 
“              .” is displayed. (“              ” is the set value.)

HLV ID Error

A Spotlight outside the ID range was 
connected to an HLV LIGHT connector.

If the channel that is connected to a Spotlight that is 
outside the ID range is selected, an error will be displayed.

Light Units that are connected to 24V 
LIGHT connectors can be set normally.

Overcurrent Error

The current consumption of the Light 
Unit exceeded 107% of the rating.

Fan Stop Error

The fan has stopped.

Clearing the Error

Output is 

stopped.

Output is 

stopped.

Normal

Recovery Method

OR

(Example display) 

Period

Check the rating of the 
LED Light Unit. Connect 
an LED Light Unit that is 
within the rating.

Press and hold the 

setting switch or 
cycle the power.

Press and hold the 

setting switch or 
cycle the power.

Operation recovers 

automatically.

Doing so may cause 
product failure.
Consult a CCS 
representative.

Check the Spotlight. 
Connect a Spotlight 
that is supported by 
the Control Unit.

If an internal error occurs in the Control Unit, it is displayed on the digital display. 

Refer to the following table and clear the error before using the Control Unit again.

11

Optional Accessories (Sold Separately)

Model: EXCB2-M10-3

External Trigger Input Cable

Connector: XG4M-1030-T (manufactured by OMRON)

Cut off on one end

10-pole MIL connector

5.2 dia.

9

1

2

10

3000

150

+

0

12

Troubleshooting

Symptom

Items to check for fixing the problem

External control is 

not possible.

Unable to turn the 

Light Unit ON and 

OFF or use strobe 

control.

Malfunctioning.

Fuming, extreme

temperature, smell,

noise, or other 

abnormality.

Is the external control cable (LAN cable) inserted firmly 

into the external control connector and an external device?

Was the command sent correctly?

Set the network settings and data correctly.

Is the external trigger input cable inserted firmly into the 

external trigger input connector and an external device?

Are the external trigger input cable and external devices 

wired correctly?

Check the connector configuration and correct the wiring.

Is the lighting mode set correctly?

Set the value to F00 for ON/OFF Mode.

Set the value to F01 to F10 for Strobe Mode.

Is the signal setting correct?

Check the setting method and sequence diagram.

Please use designated power sources with stable voltage. 

Sharing power sources with inverters, motors, etc., may 

cause malfunction.

Do not bundle product cables with high-voltage lines or power 

lines. Doing so may cause the product to malfunction. Keep 

the product cables as far away from such lines as possible.

There is a possibility of product failure. Please stop usage 

immediately and turn OFF the power switch. 

Please do not attempt to use or repair the product, since it 

is dangerous, but contact CCS Inc.

If you have any problems during product usage, please look up the cause in this chart. If the situation does not improve, or an unexpected situation 

occurs, please contact CCS Inc.

3

3

8

5, 6

6, 7

8

-

-

-

Symptom

Items to check for fixing the problem

Reference

page

Reference

page

Lights not 

illuminating.

Light intensity 

control is not 

possible.

Are all power sources turned ON?

Is the LED light cable inserted firmly into the output connector?

Is the AC cord inserted firmly into the AC inlet and a wall 

socket?

Does the digital display show an error?

Check the error display.

Is an appropriate Light Unit connected to the output 

connector? Check the Light Unit.

Is the output connector the correct one for the connected 

Light Unit? Connect 24V DC Light Units to the 24V LIGHT 

connectors and Spotlights to HLV LIGHT connectors.

Is the lighting mode set correctly?

Set the lighting mode to F00 for Continuous Mode or 

ON/OFF Mode.

Does the logic of the trigger signal match the trigger 

signal setting switch?

Is the external trigger input OFF (in ON/OFF Mode or Strobe 

Mode)? Check the setting method and sequence diagram.

Is the manual/external switch set correctly?

Set it to MANU to operate manually and to EXT for 

external control.

Is an appropriate Light Unit connected to the output 

connector? Check the Light Unit.

Is the output connector the correct one for the connected 

Light Unit? Connect 24V DC Light Units to the 24V LIGHT 

connectors and Spotlights to HLV LIGHT connectors.

Have the wrong channels been selected?

Check the channels whose lights are to be controlled.

Is the setting switch locked?

Press and hold the setting switch for more than two 

seconds to release the lock.

3
3
3

4

5, 6

8

8

9

5, 6

4

4

4

5, 6

5

Digital display

When detecting the error during external control, command will be received as 

acknowledgement for checking status (over current confirmation) command “C”. 

(This applies only to overcurrent errors and fan stop errors.)

Error Output

* Immediately after the error, occurrence of an error will be noticed only one time 

by using UDP protocol. Notify data is the same as checking status (over current 

confirmation) command “C”.

For details, refer to 8. Control with External Signals.

Error

Status

(Unit: mm)

Содержание Lighting Solution PD3-5024-4-EI

Страница 1: ...eign matter from the electrodes Failure to do so may result in fire Do not connect any Light Units other than CCS LED Light Units Doing so may cause overcurrent and the device may overheat or ignite P...

Страница 2: ...t outlets Insufficient ventilation may cause heat to accumulate inside the product and result in a fire Mounting the Unit to DIN Rail Mounting to DIN Rail Hook the tab on the upper part of the Unit on...

Страница 3: ...us Mode refer to items and under 7 Manual Control 1 3 2 To use manual control in ON OFF Mode refer to items and under and 7 Manual Control 1 3 2 9 Inputting the External Trigger The Light Units are tu...

Страница 4: ...rrent control Per connector 3 9 W max 700mA max Depends on the light intensity of the Light Unit Only connected Light Units can be selected Detected at any time 3 s 10 5 6 5 6 5 6 5 6 7 10 8 5 5 10 10...

Страница 5: ...to turn ON the Light Units continuously To flash the strobe turn the setting switch and select a setting from F01 to F10 strobe time of 40 s to 40 ms The Light Units are turned ON for the period of ti...

Страница 6: ...only 6 Lighting Mode Settings Select the lighting mode form Continuous Mode ON OFF Mode or Strobe Mode The lighting time can be set in Strobe Mode The Strobe Mode can be set for 24V DC Light Units onl...

Страница 7: ...00N014FCRLF 02F07584CRLF Setting example Setting the L3 light intensity to 75 Send data Receive data when OK Receive data when NG when there is a command error Setting the Lighting Mode 4 01OF0CRLF 01...

Страница 8: ...Units turn ON when the photocoupler is OFF and OFF when the photocoupler is ON Strobe Mode Photocoupler OFF Photocoupler ON Light Unit status Photocoupler OFF Photocoupler ON Light Unit status Photoc...

Страница 9: ...wer sources with inverters motors etc may cause malfunction Do not bundle product cables with high voltage lines or power lines Doing so may cause the product to malfunction Keep the product cables as...

Страница 10: ...10 15 70 VA 50 60 Hz 15 A at 100 VAC 30 A at 200 VAC from a cold start 3 5 mA max 264 VAC 60 Hz with no load 24V DC 1 500 VAC for one minute Cutoff current 10 mA 500V DC 20 M min Temperature 0 to 40 C...

Отзывы: