   About delay time

It takes 16μs max. response time to react after this interface unit recieves the trigger.  If the 

delay time is set, it will light after the response time followed by set time delay.

Operating instructions

15

6

Operating instructions

3. Light control and light pulse width setting (R)

This function makes it possible to register light control data (L1 and L2) and light pulse width set 

values by scene as well as a maximum of 8 scene data.  The scene data registered are saved in 

this interface unit.

Header

Code

Scene 

No.

Light control 

data (L1)

Light control 

data (L2)

Light pulse 

width

Check 

sum

Delimiter

@

R

9

999

999

999999

FF

CR

LF

Registration command

Function

Setting procedure

Light control 

data

Setting data in the range of 

0 to 256 steps with the PWM 

control system.

0 step: Light control rate; 0%
256 steps: Light control rate; 100%
Default value: 128 steps, Light control rate 50%

Light pulse 

width

Setting pulse width for strobe 

light.

The light pulse width can be set in the range of 

16 to 100,000μs.  However, Setting need to be a 

total of 6,250 steps in 16-μs units.  If the set time 

cannot be divided by 16μs, please round it up.
Example: To set to 500μs,

500/16 = 31.25 (round up to 32)

32X16 = 512

Thus, 512μs is output.

Default value: 100,000

Used to call from this interface unit scenes registered in the “3. Light control and light pulse width 

setting” section.  Used the scene called as the output data to control lighting.  Scenes No. 1 to 8 

are called.

Call command

Header

Code

Scene No.

Check sum

Delimiter

@

C

9

FF

CR

LF

4. Scene call (C)

Operating instructions

16

6

Operating instructions

In-Sight 

vision sensor

Tool bar ON/OFF 

button

External control by In-Sight Explorer

trigger signal

Port No. 0
Port No. 1

Light control data

16μs max.

Delay time

0 to 1008μs

Light pulse width

16 to 100000μs

In-Sight Explorer Window

1. Boot up the In-Sight Explorer.

(1) Select “Open the job” in the “File” menu list.

(2) Select the In-Sight vision sensor connected to this interface unit from the 

In-Sight network.

(3)Click on “Offl ine” to set the network to offl ine mode.

Initial setting of In-Sight Explorer

Содержание DIL-5000-WV

Страница 1: ...rmation Copyright c 2007 CCS Inc All Rights Reserved Description in this user manual is based on the information as of June 2007 KZ01115 T001 001 Thank you for purchasing this CCS s Interface unit for In Sight5000 series In order to properly use this product please read this User Manual before using and keep it for your future references User Manual Model DIL 5000 WV Interface unit for Cognex In S...

Страница 2: ...いただき その機能を十分活かしていただくために ご使用の前に必ず本説明書をお読み ください また 常にご覧いただけるよう 大切に保管してください 取扱説明書 型式 DIL 5000 WV In Sight5000シリーズ用 インターフェースユニット Do not use the product by any means in the following situations Conditions or an environment not described in this user manual For nuclear power control railways aircraft any other vehicles combustion equipment medical applications amusement devices or safety devices Situati...

Страница 3: ...y environment This may result in fire due to internal temperature rise Always ground power cord Otherwise it may result in electric shock Be sure to use lights connected to the product within its rating Using lights excessing the rating may result in a malfunction of the product Do not connect lights other than CCS lights to this product Doing so may result in a malfunction Connecting any lights o...

Страница 4: ... 3 Pin No 12V output type L1 Light 1 24V output type L2 Light 2 1 12V 24V 2 OUT1 NC 3 OUT2 Notes 1 Connect nothing to NC 2 Do not cause a short circuit between output and 3 A total of two channels 28W max Operation panel Interface unit Operation panel Digital window Operation button Channel indication lamp External control indication lamp Nameplate Output connector socket side for the In Sight5000...

Страница 5: ...lease refer to information in Chapter 5 Connecting wires To make use of holes for mounting in this interface unit Use M5 screws Need to make Ø6 0 7 0 holes through the fixed place To fix to the fixed place with screws Use M4 screws Need to make M4 holes for mounting in the fixed place M4 fixing screw provided 4 pieces Interface unit In Sight5000 series Break out cable B r e a k o u t c a b l e Eth...

Страница 6: ...erioration Operation procedure Procedure for operation using the operation panel This procedure is used to make setting of light control rate through operating the buttons on the operation panel of this interface unit Initial state No display on the window Channel selection Pressing any of the three buttons will display 128 on the window Press the or button to select L1 or L2 Before using In Sight...

Страница 7: ...urned OFF In this case turn OFF the power supply and then rectify the error To reset the error turn ON the power supply again Error display The window displays the overcurrent error of L1 If this error is detected the light will be turned OFF forcedly In this case turn OFF the power supply and then rectify the error To reset the error turn ON the power supply again The window displays the voltage ...

Страница 8: ...ternal control equipment such as PLC Port No 1 Using the high speed output HSOUT1 from a camera the In Sight5000 series as the trigger Note When the Port No 1 is selected the HSOUT1 cannot be used in equipment other than this interface unit Default value Port No 0 Delay time Setting a delay time prior to LED light pulse Setting in the range of 0 to 1 008μs However setting need to be total of 64 st...

Страница 9: ... light The light pulse width can be set in the range of 16 to 100 000μs However Setting need to be a total of 6 250 steps in 16 μs units If the set time cannot be divided by 16μs please round it up Example To set to 500μs 500 16 31 25 round up to 32 32X16 512 Thus 512μs is output Default value 100 000 Used to call from this interface unit scenes registered in the 3 Light control and light pulse wi...

Страница 10: ...ting in the Sensor menu 2 Select an external control equipment to be recognized by Input Module in the Discrete Input Setting menu 3 After the completion of selection click the OK button To use the extension I O module 1450 or 1460 from Cognex Select Extension I O Module To use any external control equipment other than that aforementioned Select Standard 3 Make serial port setting 1 Select Serial ...

Страница 11: ...please make this setting according to operating environments To use the extension I O module 1450 or 1460 from Cognex Check to be sure that Extension I O Module is selected in the Output Module menu list Select Acquisition Start in the Type menu list of the trigger HSOUT1 High speed output HSOUT1 from the In Sight5000 is used as the trigger 1 When the Trigger Port No 0 is used 2 1 To use other ext...

Страница 12: ... to transmit every scene data to the DIL interface unit and save it in the internal memory 4 Call the Scene button Used to call scene data saved in the internal memory of the DIL interface unit For detail of strobe setting please refer to information on page 14 For detail of settings of light control and light pulse width please refer to information on page 15 Call the Scene 2 2k 4 7k TRG TRG 4 7k...

Страница 13: ...e buttons is pressed the display light will be on Other display 6 Operating instructions 24 Operating instructions 23 6 Operating instructions The set values of light control data Light1 Light2 and pulse duration can be registered by scene Furthermore a maximum of 8 scene data can be registered The scene data registered are saved in the internal memory of the DIL interface unit When an equipment c...

Страница 14: ...shootings Symptom What to inspect and repair In case of operation panel In case of external control serial communications Light is dark Is the light control setting correct Check the setting method and then resetting of the light control data Reference page p 11 Reference page p 15 There is a possibility of product failure Please contact CCS Inc please refer to the back cover Is the shutter timing...

Страница 15: ...aximum electric current output Error display on the digital window After the error is rectified reset it by turning ON the power supply again Overpower protection Activated with more than 28W combining channel 1 and 2 Input Protection Error voltage detection 24V DC 10 max 5 min Connector Input M12 connector SACC E12MS 8CON M16 0 5 mfd by Phoenix Contact Output In Sight side M12 connector eight pol...

Страница 16: ...er manual and other written cautions during the indicated warranty period of two years CCS Inc will repair or replace the product free of charge if its radiant quantity should drop to 50 or less of its initial radiant quantity under normal use in accordance with the User manual and other written cautions during the indicated warranty period of one year CCS Inc will charge a repair fee under the fo...

Отзывы: