Operating instructions
11
12
Light control rate setting
If the figure displayed on the digital window blinks, the setting will be enabled.
Press the “ ” or “ ” button to make setting of light control data.
The setting can be made in steps of “1” each time when the button is pressed.
Pressing and holding either button will enable setting in steps of “10”.
Light control data can be set in steps of “0” to “256”.
Operating instructions
The window displays the overcurrent error of L2.
If this error is detected, the light will be forcedly turned OFF. In this case, turn OFF the
power supply, and then rectify the error. To reset the error, turn ON the power supply
again.
The window displays the overpower error of L1 and L2.
If this error is detected, the light will be forcedly turned OFF. In this case, turn OFF the
power supply, and then rectify the error. To reset the error, turn ON the power supply
again.
Error display
The window displays the overcurrent error of L1.
If this error is detected, the light will be turned OFF forcedly. In this case, turn OFF the
power supply, and then rectify the error. To reset the error, turn ON the power supply
again.
The window displays the voltage error of the power supply.
If this error is detected, the light will be forcedly turned OFF. In this case, turn OFF the
power supply, and then rectify the error. To reset the error, turn ON the power supply
again.
Other display
If there is no key operation performed for 10 seconds, the display will be turned off. If
any of the three buttons is pressed, the display will reappear.
Press the MENU button to finalize the light control data.
6
Operating
instructions
6
Operating
instructions
Pressing the MENU button will shift to light control rate setting sequence.