background image

Flexible Numbering 
Hold Music (11 Types) 
Hold Music - Volume Setting 
Hot Line to Junction 
Hot Line to Extension 
Junction Access During Power Failure 
Junction Access Codes / Change 
Junction Access in Circular / Sequential Mode 
Junction Access Control 
Junction Dialing Controls 
Junction Call Hold  + Tr Making multiple calls 
Junction Dialing Delay Time 
Junction Grouping 
Junction Line - FLASH 
Junction Line Ring Assignment 
Junction Line - Enable / Disable 
Junction to Junction Forwarding (Optional) 
LCR (Least Call Routing) - Manual 
Memory Dialing 
Operator Extension Setting 
Password 
Redial 
Remote Programming 
Resetting the PBX programming 
Ring Time Settings 
Troubleshooting 
Technical Specifications 
Terms of Warranty 

NOTE-Copper  Connections  reserves  the  right  to  alter  equipment  specifications  and  description  contained  herein  and 

makes no commitment to update or keep current the information herein. All information herein is subject to change 
at any  time  without notice.  No  part  of  this  publication  shall  be  deemed  to be  part  of  any  contract  or  commitment 
whatsoever.  

         - Product specifications and features are subject to changes without prior notice due to our constant endeavor to improve 

the product. 

         -  All  features  mentioned  in  this  manual  are  not  part  of  standard  systems.  Some  features  need  optional 

hardware/software up-gradation. 

         - Not every feature in this manual is likely to have been installed in your system or extension. 

                              

.

                                                                                      

Introduction                                                                             

.

 

All Junction lines of the PBX are  
Disabled in default. To enable them 

refer heading “Junction Line - Enable / Disable

 

Model 

Junction Lines 

              Extensions 

Door Phones 
Interface 

Door Locks 
Interface 

308 S 

Numbered as 1 
to 3 having 
access code as 
#11, #12 & #13 

-

 

Numbered as 601 to 608 

-

 

602 is the Operator. 

-

 

Programming can be done from 
601, 602, 603 & 604 

          2 
1 Door Phone 
consumes 1 
Extension port. 

        2 
2

nd

 Lock 

Operation is 
OPTIONAL 

416 S 

Numbered as 1 
to 4 having 
access code as 
#11, #12, #13 
& #14 

-

 

Numbered as 601 to 616 

-

 

602 is the Operator. 

-

 

Programming can be done from 
601, 602, 603 & 604 

         2 
1 Door Phone 
consumes 1 
Extension port. 

   None 
 

432 S 

Numbered as 1 
to 4 having 
access code as 
#11, #12, #13 
& #14 

-

 

Numbered as 601 to 632 

-

 

602 is the Operator. 

-

 

Programming can be done from 
601, 602, 603 & 604 

         2 
1 Door Phone 
consumes 1 
Extension port. 

 
 
       2 
 

 

 

.

                                                                                                 

Installation                                                                               

.

 

Cabling 

   - 

All cables of the EPABX should be at least 6” away from the electrical cables. 

   - 

They should be at least 12” away from the area of high frequencies like tube light  

Содержание COX-308S

Страница 1: ...perations Auto Attendant Mode settings Auto Attendant Message Modes Auto Attendant Voice message of 8 Secs Auto Attendant Voice message of 20 Secs Auto Attendant Playing a Company message while the ca...

Страница 2: ...ect to changes without prior notice due to our constant endeavor to improve the product All features mentioned in this manual are not part of standard systems Some features need optional hardware soft...

Страница 3: ...with the following points of the Jack Tip point of the Plug in case of the 2nd Door Lock Next to the Tip point of the Plug in case of the 1st Door Lock The above shorting acts as a simple switch Note...

Страница 4: ...nes Allowed Table Numbers to be allowed to extensions whose L 0 are to be defined in this table For value of L refer Junction Dialing Controls This table has 16 Locations Procedure Dial 0000 43 QQ ABC...

Страница 5: ...ttendant Mode The PBX can attend a Junction call at a time To attend to 2 Junction calls simultaneously an Optional card is to be added to the PBX Following are the options to attend to the Junction c...

Страница 6: ...coming Junction call is ringing on defined Extension Operator Keep the Junction in Auto Attendant Mode Record Auto Attendant message in 20 Seconds message mode Dial 0000 1670 Junction calls will ring...

Страница 7: ...n in case of Call Forward can be changed using the following program Dial 0000 184 TT Where TT 01 99 Ring Time in seconds Default value 20 secs Note The time entered here should be less than the Inter...

Страница 8: ...the LCD of the CLI phone CLI Digits addition Some CLI Telephones cannot display less than 4 digit numbers In that case if the PBX extension numbers are less than 4 digits then additional dummy number...

Страница 9: ...2 wires on the Terminal block These 2 wires are to be connected to any of the Extension port from 601 to 616 of the PBX To define the Extension as the first Door Phone extension program as below Dial...

Страница 10: ...rinted on the MDF even if flexible numbering is done ABCD The new Extension number For less than 4 digits dial at the end Of Extension Number If all the new numbers to be made in sequence then followi...

Страница 11: ...s Change Junction lines can be accessed in rotation by dialing 9 To access a particular Junction line dial 11 12 13 14 11 represents the first junction Line and 14 the last one The Junction access cod...

Страница 12: ...nsferring extension is busy the Junction call will be disconnected by the PBX If the user wants to disable this auto call back in case of No Answer while transferring a Junction call program as below...

Страница 13: ...setting Then program as below Dial 0000 0720 0731 0733 0770 0789 Junction Line FLASH To send FLASH on Junction line for using Call Waiting on the Telephone Line do the following FLASH while talking o...

Страница 14: ...imultaneous Ring i e some extension would ring in Simultaneous mode and some in Round Robin mode for the same Junction Line ring The Round Robin for Internal Calls can be Enabled Disabled through the...

Страница 15: ...cial Junctions to make Junction calls For Programming procedure refer Junction Grouping Memory Dialing User can store up to 96 Telephone Numbers in the PBX Those numbers can be dialed by any extension...

Страница 16: ...all the program of the PBX except Flexible numbering Junction Enable Disable to default values Dial 0000 0000 To erase only Flexible numbering of the PBX Dial 0000 9000 Ring Time Settings Two type of...

Страница 17: ...uthorised modifications unauthorised connections unauthorised repairs including but not limited to use of unauthorised spare parts in repairs misuse neglect abuse accident alteration improper installa...

Отзывы: