TECHNICAL CHARACTERISTICS
General
Dimensions (l x h x d) in
mm Weight
Power supply
Protection Index
300x150x90
2 kg
230V / 50Hz
IP-55
Class II
pH-meter
Measurement range
Measuring resolution
Sensor
Calibration
Correction (offset)
Dosing Pump
Type
Max. flow rate
Dosing
Volume control
3.9 to 9.9
+/- 0.1
Combined electrode
at pH 7 and pH9
+/- 0.5
Peristaltic flow
1.8 l/h
Proportional 0 to 0.9l/h
Daily and total
RedOx Analysis
Measurement range
Sensor
Calibration
10 to 990mV
Combined electrode
to 650mV
Accessories supplied
•
4 m of crystal tube.
•
3 x Sockets in 50 mm
•
1 Suction strainer for pH corrector
•
1 x Injector
•
1 x pH7 Calibration solution
•
1 x pH9 Calibration solution
•
1 x 650mV Calibration solution
•
1 x pH sensor
•
1 RedOx (ORP) sensor
•
2 x sensor holders
•
1 enslaving cable
Menu 8 different languages
French, English, German, Spanish,
Italian, Portuguese, Dutch, Czech
W
HEN THE DEVICE IS IN “DOSING” MODE
,
THE PUMP DOES NOT TURN CONTINUOUSLY
BUT TURNS FOR A FEW SECONDS AT
1
MINUTE PER
2
MINUTE CYCLE
.
C
AUTION
: T
HIS EQUIPMENT IS SPECIFICALLY DESIGNED FOR CORRECTING THE P
H
OF
SWIMMING POOLS
. I
F USING ANOTHER TYPE OF SOLUTION
,
CONSULT THE MANUFACTURER TO
VERIFY COMPATIBILITY
.
HYDROCHLORIC ACID OF OVER
10%
IS NOT RECOMMENDED
.